Installing The Appliance Into The Wall - Napoleon NEFP24HT-HD Installation And Operation Manual

24” electric fireplace with trim kit
Table of Contents

Advertisement

Available languages

Available languages

installation
EN

4.5.2 installing the appliance into the wall

Prepare rough in framing following the recommended dimensions, see Figure 1.
Select a location that is not prone to moisture and is located at 36" (91.4cm) away from combustible materials as
curtain drapes, furniture, bedding, paper, etc.
Floor
or mantel base
Fig.1
FIREPLACE / MANTEL OPENING DIMENSION REQUIREMENTS
A
B
Min. 23" (58.4cm) / Max. 35" (88.9cm)
C
Min. 17 1/4" (43.8cm) / Max. 22 1/2" (57.1cm)
F
1. Once the rough opening has been prepared and the power has been routed to the right side of the recess,
the appliance may be installed.
2. The electrical connection must be made prior to placing the appliance into position, see "hard wiring
installation" section.
14
W415-1755 / 05.03.17
A
3-SIDED TRIM
Min. 9" (22.9cm)
Min. 0"
F
B
4-SIDED TRIM
Min. 9" (22.9cm)
Min. 23" (58.4cm) / Max. 35" (88.9cm)
Min. 17 1/4" (43.8cm) / Max. 22 1/2" (57.1cm)
Min. 6.5" (16.5cm)
Fig.1
(58.4cm)
41"
(104.1cm)
C
(73.6c