Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Refrigerant The Zip HydroChill contains R134a refrigerant under pressure. Maintenance of the refrigeration unit Installation instructions & user manual Technical support 806310UK V1.00 July 2019 - HydroChill HC05...
The HydroChill must be sanitised during the commission process, please contact the Zip Water team on 0345 6 005 005 to book your commissioning service. For water taste and quality reasons any non-use of more than 48 hours, Zip recommend a system flush be performed.
Technical data Dispense Dispense Power rating Dimensions Weight Range Model Refrigerant options rating W x D x H (mm) Empty Kg* HydroChill HC05T128 Chilled 28 litres/ hr 0.345 R134a 350 x 350 x 915 28.5 * Weight is chiller unit only with no accessories •...
• Ensure the floor can support the product weight when full of water (allow an extra 4kg when full). • For Zip HydroChill floor standing models, 1 x 230V AC 13A socket will be required. • The HydroChill must be installed in accordance with IEE regulations, See Technical specification, page 4 for power ratings.
Installation - Section 1 Water block (optional) 1.0 Description • The Water Block is designed to be installed upstream of any Zip product and associated pipe- work to minimise the potential for water leakage in the event of a system malfunction. •...
Page 8
The reset device (see Fig.2) may be fitted to avoid disconnection. This allows the Water Block to be reset by operating the lever in the direction shown in Fig.2. • In the event of persistent tripping contact Zip for advice on 0345 6 005 005. 1.4 Maintenance •...
Installation - Section 2 Ventilation 2.0 Clearance envelope For safe and efficient operation of the HydroChill, the following ventilation clearance envelope must be observed. 50mm back clearance 50mm RHS side clearance 400mm 300mm LHS side clearance Installation instructions & user manual Technical support 806310UK V1.00 July 2019 - HydroChill HC05 Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Installation - Section 3 Tap installation 3.0 Configure the heavy duty tap Heavy duty Tap spout o -rings Bearing Allen key Grub screw Tap base Disassembled Assembled • The tap base is ready attached to the HydroChill. • To fit the spout, unscrew the grub screw at the back of the tap base , in order that it does not foul the o-rings &...
Installation - Section 4 HydroChill installation 4.0 installation instructions, floor standing HydroChill Read these instructions before commencing HydroChill installation, they apply to all installation arrangements. • Install the mains water pipework before locating the HydroChill in place. (See diagram below). •...
Once your system is installed it is recommended that during the commissioning process it is sanitised to the current guidelines before first use. Zip HydroChill models have a free commissioning service please contact us on 0345 6 005 005 to book your visit.
Rotate • Use only a Zip filter to match the one used in your chiller product (see Spare parts page 5). The filter cartridge can be obtained directly from Zip, visit www. zipwater. co.uk or alternatively call Zip on 0345 6 005 005.
• Before calling for service, check that both the water and electricity supplies are turned on and functional. • Call Zip customer service on 0345 6 005 005 for assistance, service, spare parts and enquiries. Filter Timer Module • The 2x AAA batteries should be replaced when filter is replaced.
Maintenance Condenser • The condenser should be cleaned at regular 12-monthly intervals, or when the filter is replaced. • The condenser is accessed by a removable panel in the side of the external case. Disconnect power and remove the 4 screws holding the panel in place , see adjacent diagram.
Ensure that all electrical connections to the HydroChill are secure and that the unit has had adequate time to cool down. • Call Zip customer service on 0345 6 005 005 for assistance, service, spare parts and enquiries. Symptom Possible Cause Solution Mains water not connected or turned on Connect or turn on water supply.
Service Work Ad hoc repairs by Zip or its approved service providers are covered under Warranty for 30 days in relation to the original fault only. If you are a HydroCare Service Plan subscriber please refer to the HydroCare terms and conditions for information on applicable warranties and warranty periods for HydroCare services.
Page 18
Notes Installation instructions & user manual Technical support 806310UK V1.00 July 2019 - HydroChill HC05 Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...