Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
Safety Instructions Caution 1.The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Page 4
Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
Page 5
Caution ■When handling the unit or assembling/replacing units: •Do not touch the sharp metal parts of the connector or plug for connecting units. •Take care not to hit your hand when disassembling the unit. The connecting portions of the unit are firmly joined with seals. •When joining units, take care not to get fingers caught between units.
Page 6
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
Page 7
■NOTE ○Follow the instructions given below when designing, selecting and handling the product. ●The instructions on design and selection (installation, wiring, environment, adjustment, operation, maintenance, etc.) described below must also be followed. Product specifications •Use the specified voltage. Otherwise failure or malfunction can result. •Reserve a space for maintenance.
Page 8
Environment •Select the proper type of protection according to the environment of operation. IP67 protection class is achieved when the following conditions are met. (1) The units are connected properly with fieldbus cable with M12 connector and power cable with M12 (M8) connector.
Page 9
Maintenance •Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of air before performing maintenance. There is a risk of unexpected malfunction. •Perform regular maintenance and inspections. There is a risk of unexpected malfunction. •After maintenance is complete, perform appropriate functional inspections.
Page 10
SMC Wireless System Features The SMC wireless system has the following features. - Quick start-up takes 0.25 sec.(minimum) to connect to the system when the remote is powered. - Parameter setting by Near Field Communication (NFC) using a PC (no HW setting). - A maximum of 127 remotes can be registered to one base - The maximum number of I/O points of wireless system is 1280 for input and output.
Page 11
SMC Wireless System ■ Outline This system is an I/O distributed system which can be wirelessly connected. It consists of a combination of a base and remote that has a wireless function with the upper-level device. The base can be combined with an EX600 series I/O unit . Module configuration can be constructed. (See page 11.) The base can have max.
Page 12
■System configuration < Connectable devices > Pressure switch, flow switch, auto switch, other switches (proximity / photoelectric / limit switch, etc.) Wireless system configuration example...
Page 13
■Definition and terminology Terminology Definition Abbreviation of functional earth. The word "earth" refers to this functional earth. Abbreviation of Near Field Communication. Non-contact short distance wireless communication. It is accessible using a card reader/ writer by using a special application. Abbreviation of Product ID.
Mounting and Installation ■Installation - Direct mounting EX600-WD□E□ Mount the unit with M4 screws (not included) using the two holes of the unit. (Tightening torque: 1.35 to 1.65 Nm) Recommended mounting hole dimensions EX600-WD□A□ Mount the unit with M5 screws (not included) using the four holes of the unit. (Tightening torque: 2.7 to 3.3 Nm) Recommended mounting hole dimensions...
How to Order Input/Output specifications PNP type Connector Notes 2 points / 1 connector Grommet M12 connector (16 points) 1 point / 1 connector e-CON connector (8 points) Input/Output specifications Digital input Digital output...
Summary of Product parts ○EX600-WDXE1 Description Application This area is in close contact with the NFC reader / writer. Area close to NFC antenna "O" is the center of the NFC antenna. Status LED LED display to indicate the unit status. Screw hole for mounting (M4 x Holds the remote.
Page 17
○EX600-WDXA1 Name Application This area is in close contact with the NFC reader / writer. Area close to NFC antenna "O" is the center of the NFC antenna. Status LED LED display to indicate the unit status. Screw hole for mounting Used for installing sheet metals.
Page 18
○EX600-WDYA1 Name Application This area is in close contact with the NFC reader / writer. Area close to NFC antenna "O" is the center of the NFC antenna. Status LED LED display to indicate the unit status. Screw hole for mounting Used for installing sheet metals.
Page 19
Wiring ■Wiring and Connection (e-CON type) # Input unit - Power socket connector wiring specifications Pin number Terminal 24 V (for control and input) N.C. 0 V (for control and input) N.C. - Wiring of the socket connector for input equipment Pin number Terminal 24 V (for control and...
Page 20
# Output unit - Power socket connector wiring specifications Pin number Terminal 24 V (for control and input) 24 V (for output) 0 V (for control and input) 0 V (for output) - Wiring of the socket connector for output equipment Pin number Terminal N.C.
Page 21
■Wiring and Connection (Grommet Type) # Input unit - Pairing cable: M12 4-pin plug (male) Description signal number Connector the short jumper connector - When connected: Normal operation mode - When not connected: Pairing mode Mating connector : M12 4-pin socket A code - Pairing supply cable: M12 4-pin plug (male) Description signal...
Page 22
- Input unit circuit Power supply Input cable x 8 (0 to F) cable Pin No.1 Pin No.1 For control and inputs 24 VDC 24 VDC Short circuit detection Pin No.2 Pin No.2 Input n+1 N.C. Pin No.3 Pin No.3 0 VDC 0 VDC Pin No.4...
Output unit - Pairing cable: M12 4-pin plug (male) Description signal number Connector the short jumper connector - When connected: Normal operation mode When not connected: Pairing mode Mating connector : M12 4-pin socket A code - Pairing supply cable: M12 4-pin plug (male) Description signal number 24 V (for control and input)
■Remote e-CON type LED indicator Input unit Remote e-CON input type LED indicator - Remote e-CON input type LED indicator specifications Color of LED name Function Single Operation Green LED Normal power supply voltage for control and is ON. input (US1) ON Status of power supply voltage for control Power supply for control and input (US1) is not...
Page 25
# Output unit Remote e-CON output type LED indicator - Remote e-CON output type LED indicator specifications LED name Function Color of LED Single Operation Normal power supply voltage for control and input Green LED (US1) ON, and normal power supply voltage level is ON.
Page 27
■Remote grommet type LED indicator # Input unit Remote grommet input type LED indicator - Remote grommet input type LED indicator specifications LED name Function Color of LED Single Operation Green LED is Normal power supply voltage for control and Indicates the power supply voltage input (US1) ON (US1) status...
Page 28
# Output unit Remote grommet output type LED indicator - Remote grommet output type LED indicator specifications LED name Function Color of LED Single Operation Normal power supply voltage for control and input Green LED is ON. (US1) ON, and normal power supply voltage level for output (US2) Indicates the power Abnormal power supply voltage level for output (US2)
Setting and Adjustment ■Flow chart for using the wireless system Step 1 Preparation before use (PC, Application) (1) Install the NFC reader, writer and driver (2) Install the I/O configurator Step 2 Setting / installation of the wireless unit (1) Parameter setting of “Remote” (optional) *: Refer to the Remote Parameter Details (page XX to XX) (2) Set the number of occupied I/O points for the module and each parameter of the "base".
Page 30
■Procedure 1 Preparation (PC application) # SMC wireless system I/O Configurator (NFC version) The I/O Configurator (NFC version) can be used to check the parameter setting of the wireless unit and the contents and status of the constructed wireless system, using an NFC reader / writer and a PC. There are two types of settable parameters which can be read or written when no power is supplied to the product and the parameters which can be read or written only when the power is supplied to the product.
Page 31
# I/O Configurator (NFC version) (1) I/O Configurator (NFC version) consists of 3 tabs listed below. Information tab - The unit information area indicates the unit information. - System configuration: Displays the configuration information of the base and remote (connected unit) - The system configuration of only the wireless master unit is shown in a tree-like profile.
Page 32
(3) The I/O Configurator has two modes: a supervisor mode which can change the parameter setting and a monitor mode which can only read the parameters. It is necessary to change the mode to the Administrator mode to set the parameters. Administrator mode: available to read and write the parameters.
Page 33
■Procedure 2 Setting / Installing the wireless unit # Wireless system parameter list - Remote (input / output) setting parameters Setting when Classification Parameter name Set value Initial value Notes not energized Output while Setting the output operation while the communication CLEAR/HOLD CLEAR...
Page 34
# Remote Parameter Details The following two settings need to be performed to set the parameters of the remote. (1) Remote setting (2) Pairing setting (1) Remote setting - Output while communication is not established Define all settings in the output operation status when the fieldbus communication is disconnected. Clear: Clear the output.
Page 35
(2) Pairing setting Setting for wireless communication between the base and remote. The required setting for wireless registration of the remote is Pairing (change of operation mode) only. After changing the operation mode in the pairing setting, the mode is changed by clicking the Reset button or re-supplying power so that the mode will be changed to the base registration or listing for connection.
Page 36
# Remote registration Registration for wireless communication between the base and remote. For this wireless system, it is necessary to register the PID (Product ID) of each product to establish communication without interference from another network. The minimum required settings for registration of the base are pairing (change of operation mode) and remote registration.
Page 37
# Wireless unit registration procedure - Registration procedure for the base and remote (1) Change of operation mode of the remote (1) e-CON type Normal operation mode *: Pairing performed *: Default value Pairing not performed Release the Fn button >8 sec Keep pressing the Fn button >...
Page 38
(2) Grommet type 1. Disconnect the power connector and turn off the power. 2. Disconnect the short jumper connector for the pairing cable. 3. Connect the power connector again to turn on the power. By following this procedure, the remote grommet type does not require the NFC. Operation mode change for the base is necessary.
Page 39
(2) Change of operation mode of the base. Enable the pairing setting of the remote registration on the base and reflect the change by clicking the Reset button or by re-supplying power. Then, update the contents on the screen by clicking the Refresh button.
Page 40
- Registration should be performed with power supplied to both the base and remote. - For the Input size and Output size of the remote, the setting of wireless registration will be reflected to the base. When changing the number of Input and Output points of the remote, pairing should be performed again.
Page 41
# Dummy remote The dummy remote can register a "Dummy area" in the I/O map. A remote can be added without changing the I/O map by registering the remote to the "Dummy area" even after system construction. The remote allocation order to the I/O map is from the smallest channel to the largest channel registered by the wireless channel which has been set during remote.
Specifications # Input unit (e-CON type) specifications Electrical specifications Items Specifications Power supply for control and input (US1) 24 VDC +/-10% Current consumption 100 mA or less Control point 1 connector Shaft type PNP(-COM) Connector type e-CON (4 pins) 0.3 A/ connector Max.
Page 45
NFC communication specifications Items Specifications Communication standard ISO / IEC 14443B (Type-B) Frequency 13.56 MHz ~1 cm Communication distance *: The NFC communication RFID tag of the 13.56 MHz passive type. Remote (input / output) setting parameters Classification Parameter name Initial value Occupied points for the 16 points (2 byte)
Page 46
# Output unit (e-CON type) specifications Electrical specifications Items Specifications Power supply for control and input (US1) 24 VDC +/-10% Current consumption 50 mA or less Output power supply voltage (US2) 24 VDC +/-10% Number of points 8 points (1 point / connector) PNP (-COM) Output type Output...
Page 47
NFC communication specifications Items Specifications Communication standard ISO / IEC 14443B (Type-B) Frequency 13.56 MHz Communication distance Up to 1 cm *: The NFC communication RFID tag of the 13.56 MHz passive type. Remote (input / output) setting parameters Items Parameter name Initial value Hold / Clear (unit)
Page 48
# Input unit (grommet type) specifications Electrical specifications Items Specifications Power supply for control and input (US1) 24 VDC +/-10% Current consumption 100 mA or less Number of points 16 points (2 points / connector) Output type PNP (-COM) Connector type M12 5-pin socket 0.3 A/ connector Max.
Page 49
NFC communication specifications Items Specifications Communication standard ISO / IEC 14443B (Type-B) Frequency 13.56 MHz Communication distance Up to 1 cm *: The NFC communication RFID tag of the 13.56 MHz passive type. Remote (input / output) setting parameters Classification Parameter name Initial value Occupied points for the...
Page 50
# Output unit (grommet type) specifications Electrical specifications Items Specifications Power supply for control and input (US1) 24 VDC +/-10% Current consumption 50 mA or less Output power supply voltage (US2) 24 VDC +/-10% Number of points 16 points (2 point / connector) PNP (-COM) Output type Output...
Page 51
NFC communication specifications Items Specifications Communication standard ISO/IEC14443B(Type-B) Frequency 13.56 MHz Communication distance Up to 1 cm *: The NFC communication RFID tag of the 13.56 MHz passive type. Remote (input / output) setting parameters Items Parameter name Initial value Hold / Clear (unit) Clear Occupied points for the...
Troubleshooting When problems occur, take appropriate countermeasures while referring to the LED indication, troubleshooting and parameter settings. If a cause applicable to the failure cannot be identified, this indicates that the equipment itself is broken. The fieldbus system damage can be caused by the operating environment. Contact SMC to obtain countermeasures.
Page 53
- Remote input unit / output unit / Troubleshooting Problem Phenomenon Possible causes Investigation and countermeasures All LEDs are Supply 24V DC +/-10% for control power Power supply for control is OFF. OFF. source. The power supply voltage for output has PWR: Red LED Output power supply voltage decreased dropped.
Page 54
Problem Phenomenon Possible causes Investigation and countermeasures (1) Check that the power supply voltage for control and input (US1) is supplied to the base and remote. (2) The distance which wireless W-MS: Red (1) Power supply for the base is OFF communication between wireless LED flashing (2) Outside the wireless coverage area...
Page 55
Problem Phenomenon Possible causes Investigation and countermeasures If the polarities (PNP, NPN) of the remote and digital input unit do not match, Input type does not match. replace one of them to make the combination match. Input power supply voltage for control Check that a voltage of 24 VDC+/-10% is decreased applied.
Page 56
Accessories (1) Seal cap (10 pcs.) EX9-AWTS (2) e-CON connector ZS-28-□ Conductor cross sectional Wire O.D. Product No. AWG No. Color of cover area (mm) (mm SQ) ZS-28-C-1 Ø1.0 to ø1.2 Yellow 24 to 26 0.14 to 0.2 ZS-28-C-2 Ø1.2 to ø1.6 Orange ZS-28-C Ø1.0 to ø1.2...
Need help?
Do you have a question about the EX600-WD Series and is the answer not in the manual?
Questions and answers