Telnet
The SCU will support four concurrent Telnet sessions.
Telnet is supported via the Ethernet interface.
To use Telnet to communicate with the SCU, use the
following steps:
1. Set the proper IP Address for the connection
method of choice via the provisioning menu. For
this procedure, refer to the following page of this
practice.
2. Connect to the Ethernet Interface on the
backplane of the Total Access 1500 shelf.
3. A successful Telnet connection is established
when the following appears on the screen:
/* enter 'MENUS;' to obtain menus (characters
will not echo) */
OK 0
<
4. A TL1 session may be activated at this time or to
logon to the Total Access Menu System, enter
'MENUS;'. If Password authentication is
enabled, enter the Account Name for the Total
Access shelf, and press ENTER. The cursor will
then be placed at the Password field, waiting for
a password.
5. At the Password field, enter the Password for the
Total Access System, and press ENTER.
6. Upon entering the correct password, the Total
Access main menu is presented on the screen.
This signifies a successful logon.
Provision the Ethernet Interface Settings
If the Total Access 1500 shelf is to be connected to an
Ethernet network for Telnet, TFTP or SNMP
Management, the IP Address, Subnet Mask, and
Default Gateway must be set for the shelf to
communicate with the network.
To set the IP Address, Subnet Mask, and Gateway:
1. From the System Controller main menu, select
option 5, Management Configuration, and press
ENTER.
2. From the Management Configuration menu,
select option 1, IP Address, and press ENTER.
61180008L1-5B
The IP Address, Subnet Mask and Gateway are
in the form XXX.XXX.XXX.XXX, with the
XXX's representing 1, 2 or 3 digit decimal
numbers from 0 to 255.
3. Enter a valid IP address, and press ENTER.
4. From the Managemen Configuration menu,
select option 2, IP Subnet Mask, and press
ENTER.
5. Enter a valid Subnet Mask, and press ENTER.
6. From the Management Configuration menu,
select option 3, IP Default Gateway, and press
ENTER.
7. Enter a valid Default Gateway, and press
ENTER.
8. From the Management Configuration menu,
select option 4, Telnet Port Number, and press
ENTER.
9. Enter the port to connect to when performing
TL1 over TCP/IP. This is set to 2000 as a
default.
Menuing System
The ADTRAN Total Access SCU provides a menuing
system for the Total Access shelf. All system-related
menus are controlled by the SCU as well as some of
the access modules menus. Other access modules have
their own user menu structure supported by the
module.
Menu Structure
The menu structure for the SCU is a layered menu
tree. Each menu level consists of submenus and/or
menu items. Some menu items are restricted to certain
user accounts. The SCU supports Read-Write and
Read-Only accounts. Each of these accounts may also
be given Test or Admin privileges. The Admin
privileges allow the user to change all provisionable
settings as well as network configuration settings that
are not accessible to Read-Write and Read-Only
accounts. Examples include SNMP provisioning, TL1
provisioning, Date/Time settings, password
administration, and software downloads. The
Read-Write account allows the standard provisioning
settings to be changed. The Read-Only account allows
Section 61180008L1-5, Issue 2
NOTE
5