Item
Detection of AVC
Ensure the following:
Connection Condition
(1) If AVC and LCD is disconnected, or
(2) AC supply for AVC is off,
LCD Front LED will be: Orange (Blinking)
LCD Power state will be: Stand-By Mode
LCD Individual
It must operate by the LCD independent.
Burn-in Function
It must give a change indication of whole surface
monochrome.
Measuring
To answer the accumulated time of ON mode
Accumulated
by the request of AVC.
ON time
EEPROM
If the address of EEPROM doesn't have the
Automatic
designated data below, ensure
Initialization
initialization is executed, and the data is written.
Key Operation
Sub Power SW: To be able to change-over
ON/Stand-By mode.
SII169 Configuration
When the power is ON, store the data at the
DATA Setting
SII169 Configuration EEPROM
(I002 BR24L08FJ) for data storage.
(1) When the power is turned ON for the first
time, conduct the writing.
(2) From the next time, check the data every
time the power is turned ON, and if it isn't the
designated data, overwrite the correct one.
Specification
EEPROM Address
Designated Data
The operation starts by pressing
Sub power SW for 5 seconds.
Turn off the Sub SW to cancel.
automatic
'
'
27