Install Chiller (customer
supplied)
The following instructions apply to tank modules
(24C317, 24D562, 24D564, 24D565) that include the
heat exchanger assembly (G).
NOTE: Graco does not supply the chiller assembly.
1. Connect incoming water to inlet heat exchanger
port.
2. Connect outgoing water to outlet heat exchanger
port.
ti16671a
F
. 9: Heat Exchanger Assembly
IG
3. Configure the advanced display module (ADM) for
the chiller option. See the HFR or VRM Setup-Oper-
ation manual for instructions.
3A1299K
Water Inlet
Water Outlet
Auto-Refill Installation:
customer supplied feed system
NOTE: The auto-refill assembly is not assembled
when shipped.
1. Empty tank (C).
2. Remove plug from top of tank.
3. Install auto-refill assembly in 3/4 npt port.
4. Connect hose (not supplied) to 1/2 npt port on mate-
rial valve.
Air Line
F
. 10: Tank Assembly
IG
5. Connect air lines from air valve (A) to material
valve (D).
6. Connect main air line to air valve.
Installation
Air Valve
Material
Valve
Air Solenoid
Valve
ti16668a