15V534 Gun Flush Box Interface Kit 313212B ® Interfaces a Graco Gun Flush Box with a ProMix 2KS Electronic Proportioner using a RoboMix Fluid Station. For professional use only. Approved for use in explosive atmospheres only when used in conjunction with ProMix 2KS Electronic Proportioners.
Installation Installation Location Install the gun flush box module enclosure (1) within 15 ft (4.5 m) of the RoboMix, to ensure that the cable (23) will reach the RoboMix. The module is approved for use • To avoid electric shock, ground all equipment. in a hazardous location.
Installation Install the Cable 3. Connect the cable wires to the left side of the termi- nal strip (12), as indicated by the label (20). See F 2 and Table 1. 1. Loosen the captive screws and remove the front cover from the enclosure.
Installation Install the Air Flow Switch 2. Connect the wires from AFS#1 to the right side of the terminal strip (12) pins 1 (+) & 2 (-), as indicated by the label (21). See F . 4 and Table 1. NOTE: The GFB Interface Module Kit does not include an air flow switch (AFS).
Installation Install the Pressure Switch 2. Connect the wires from PS#1 to the right side of the terminal strip (12) pins 5 (+) & 6 (-), as indicated by the label (21). See F . 6 and Table 1. NOTE: The GFB Interface Module Kit does not include a pressure switch (PS).
Installation Install the Solenoid 2. Connect the wires from SO#1 to the right side of the terminal strip (12), as indicated by the label (21); red (+12V) to pin 9, black (COM) to pin 10. See F NOTE: The GFB Interface Module Kit does not include a and Table 1.
Installation Connect the Cable to the RoboMix Control Board NOTICE To avoid damaging circuit board when servicing, wear grounding strap on wrist and ground appropriately. 1. See the ProMix 2KS Repair-Parts manual. Open the RoboMix to access the control board. 2.
Installation Connect the Gun Flush Box Replace the Cover NOTE: Use 5/32 in. (4 mm) OD tubing to connect the Reinstall the cover on the enclosure and secure with the gun flush box air ports to the interface module air ports, four captive screws.
Parts Parts TI14279a 1 (Ref) TI14280a If using two gun flush boxes, remove item 5 and two of item 4. 12 (Ref) AIR FLOW SWITCH #1 + (BLK) AIR FLOW SWITCH #1 - (WHT) AIR FLOW SWITCH #2 + (RED) AIR FLOW SWITCH #2 - (GRN) PRESSURE SWITCH #1 + (ORG) PRESSURE SWITCH #1 - (BLU)
Connect a Booth Control to the RoboMix (to operate as a manual system) Connect a Booth Control to the RoboMix (to operate as a manual system) To use the RoboMix as a manual system, order the 1. See F . 13. Mount the booth control in a convenient 15V350 Booth Control Kit and connect as follows.
Dimensions Dimensions 4.00 in. 4.00 in. (101.6 mm) (101.6 mm) 6.75 in. (171.5 mm) 7.50 in. Mounting Holes (190.5 mm) 6.28 in. (159.5 mm) TI14276a TI14278a Technical Data Maximum Air Input Pressure ..... 100 psi (0.7 MPa, 7 bar) Air Inlet Size .