Heat Zone and Fluid Control Selection
The tank feed system supports independent tempera-
ture control by utilizing a low power temperature control
module. The system also supports fluid control by utiliz-
ing an FCM. Both the low power temperature control
module and the FCM are located on the electrical panel
within the enclosure.
NOTE: Tank stands are configured for the A (Red)
side. Adjust rotary switch setting if tank is being
used on B (Blue) side.
F
. 4: Electrical Panel
IG
Adjust Rotary Switch
The rotary switch setting indicates which zone the tem-
perature control module will control in the system. The
low power module and FCM use a 16-position rotary
switch to make selections.
Set the rotary switch to the specific selection according
to the settings listed in the following tables.
Rotary Switch
F
. 5: Adjust Rotary Switch
IG
3A1299K
Low Power Temperature Control Module Rotary Switch
Settings
FCM
FCM Rotary Switch Settings
Low
Power
Temp
Control
r_24C169_3A0395_1a
ti12361a
Setting
Zone
0-4
Not Used
5
B (Blue) Tank Heater
6
A (Red) Tank Heater
7
B (Blue) Chiller
8
A (Red) Chiller
9-F
Not Used
Setting
Zone
0-2
Not Used
3
B (Blue) Tank Refill
4
A (Red) Tank Refill
5
Not Used
6-F
Not Used
Component Identification