Graco 24G952 Instructions - Parts Manual page 14

Carbon steel tank stands
Table of Contents

Advertisement

Installation
CA
CB
F
. 7: Level Sensor Assembly
IG
10. Measure the length of the level sensor well housing,
and then measure the depth of the hole in the tank
where the well is inserted. Note these measure-
ments as they will be need later.
11. Being careful to not cross-threads, thread assem-
bled level sensor (CB) into well housing until it bot-
toms out against the bottom of the well. The bottom
of the level sensor will be slightly visible through the
bottom of the well.
NOTE: In the following step, do not allow PTFE
paste or tape to cover the tip of the level sensor
well. If paste comes in contact with the tip of the
level sensor well, thoroughly wipe it clean.
12. Apply PTFE paste and PTFE tape to the male
threads of the level sensor well housing.
13. Being careful to not cross-threads, thread the level
sensor well (CA) into the corresponding tank port
and lightly tighten with a crescent wrench.
NOTICE
Do not pressurize tank with level sensor removed
from sensor well. Doing so will rupture the level
sensor well.
14
CC
Wires
CD
r_24b969_3A0395a_7a
J3
J2
J1
F
. 8: Tank Ports
IG
14. Measure the amount of the level sensor well hous-
ing that is visible beyond the day tank hole, then
perform the following equation:
P = L1 - (L2 + L3)
P = Protrusion length (inside of day tank)
L1 = Length of level sensor well
L2 = Visible length of level sensor well
L3 = Length of well threads in day tank
15. The protrusion length must be at least 1/8 in.
(3.2 mm). If not, remove the level sensor well and
restart at step 10.
16. Rotate level sensor to optimal position for wire rout-
ing.
17. Plug the sensor connector (CD) into the level sen-
sors.
Ensure the level sensors are installed in the sensor
well housings before pressurizing the tank. Failing to
do so could cause the well housings to rupture, which
may result in serious injury and material leakage.
18. Plug the sensor connector into the connector on the
FCM.
19. Calibrate the sensor. See Calibrate Barrel Style
Level Sensors, page 17.
ti16670a
3A1299K

Advertisement

Table of Contents
loading

This manual is also suitable for:

24g95324g95624g95724j707 nvh

Table of Contents