Tank Heater - Bunn System III Operating & Service Manual

Bunn coffeemaker operating & service manual
Hide thumbs Also See for System III:
Table of Contents

Advertisement

SERVICE (cont.)

TANK HEATER

FIG. 27 TANK HEATER
Location:
The tank heater is located inside the hood on the
right rear of the tank lid.
Test Procedure:
Electro/Mechanical Models.
1. Disconnect the brewer from the power supply.
2 With a voltmeter, check the voltage across the
black and the red wire on the tank heater. With the
control thermostat turned to the "ON" position
(fully clockwise), connect the brewer to the power
supply and check the voltage across the wires. The
indication should be:
a.) 208 volts ac for three wire 120/208 volt models
and 240 volts ac for three wire 120/240 volt
models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.
3. Disconnect the brewer from the power supply.
BLK to Limit Thermostat
ELECTRO/MECHANICAL
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the
Wiring Diagrams and check the wiring harness.
4. Disconnect wires from the tank heater.
5. Check for continuity across the terminals of the
If continuity is present as described, reconnect the
wires, the tank heater is operating properly.
If continuity is not present as described, replace the
tank heater.
NOTE - If the tank heater remains unable to heat,
remove and inspect the heater for cracks in the sheath.
DBC Models:
P2231.35
1. Disconnect the brewer from the power source.
2. Disconnect wires from heater.
3. Check for continuity across the tank heater ter-
If continuity is present as described, the tank heater is
operating properly.
If continuity is not present as described, replace the
tank heater.
NOTE - If the tank heater remains unable to heat,
remove and inspect the heater for cracks in the sheath.
Removal and Replacement:
1. Remove wires from tank heater.
2. Remove the four #8-32 nuts securing tank heater
3. Remove tank heater and gasket.
4. Install new tank heater and gasket with four #8-32
5. Refer to Fig. 28 when reconnecting the wires.
RED to Contactor T1
BLK to Limit Thermostat
FIG. 28 TANK HEATER TERMINALS
Page 33
tank heater.
minals.
to tank lid.
nuts on tank lid.
BLU Lead from Triac Assembly
DBC
P837
27362 092996

Advertisement

Table of Contents
loading

Table of Contents

Save PDF