7-3. Servicing Filter And Spark Guard (SWX-D Models)

1
4
É É É É
É É É É
É É É É
!
!
!
!
2
!
3
1
2
3
4
Release latches and open hatch.
Use filter handles to remove filter.
Replace filter if dirty or damaged.
Wipe off hatch. Vacuum particles
from inside of housing.
Remove spark guard (from behind
baffle).
Clean and inspect spark guard
screen. Replace spark guard if
screen wires are broken or missing.
Install spark guard.
Install filter.
Close hatch and secure with latches.
Turn off and disconnect input
power.
Do not operate unit without fil-
ter or with dirty filter.
Replace the filter when dirty.
Do not clean the filter or use a
filter that has been cleaned.
Do not breathe the particles
collected by the fume extrac-
tor. Wear approved safety
equipment (respirator, gloves,
long sleeve shirt) when ser-
vicing filter and spark guard.
Dispose of used element and
collected particles according
to local, state, and federal re-
quirements.
Read and understand the Ma-
terial Safety Data Sheets
(MSDSs) and the manufactur-
er's instructions for metals,
consumables,
coatings,
cleaners, and degreasers.
Latch
Hatch
Filter
Spark Guard
Tools Needed:
Respirator
Ref. 248 191
OM-246 877 Page 39