4.
TPM9.5A LA
4.4.3
AmbiLight Panel
Refer to
Figure 4-13
for details.
1. Gently release the clamps and unplug the two connectors
[1, 2] that secure the ambilight panels. Release the clips
1
4.4.4
Small Signal Board (SSB)
Refer to
Figure 4-14
for details.
Caution: it is mandatory to remount all different screws at their
original position during re-assembly. Failure to do so may result
in damaging the SSB.
1. Release the clips from the LVDS connector that connect
with the SSB [1].
Caution: be careful, as these are very fragile connectors! T
2. Release the clamps and unplug all other connectors [2,3].
3. Remove all the fixation screws from the SSB [4].
4. The SSB can now be shifted from side connector cover,
then lifted and taken out of the I/O bracket. Refer to
Figure 4-14
for details.
2012-Nov-30
Mechanical Instructions
3
Figure 4-13 Rear cover removal
back to
div. table
from the FFC connector that connect with the AmbiLight
control panel [3].
2. Lift the AmbiLight panel from the rear cover. Make sure that
wires and flat foils are not damaged while lifting the
ambilight panel from the rear cover.
4
4
Figure 4-14 SSB removal
4.4.5
Power Supply Unit (PSU)
Caution: it is mandatory to remount all different screws at their
original position during re-assembly. Failure to do so may result
in damaging the PSU.
1. Unplug all connectors from the PSU.