Maintenance - Emerson Fisher POSI-SEAL A81 Instruction Manual

Rotary valve
Table of Contents

Advertisement

A81 Valve
January 2011
Figure 4. Packing Arrangement Details
PTFE V‐RING
GE39901‐A
GE40113‐A
SINGLE PTFE PACKING
NOTES:
1
WITH CONDUCTIVE PACKING, THE FEMALE ADAPTOR IN PTFE V‐RING PACKING
IS CARBON‐FILLED PTFE.
APPLY LUBRICANT.
2
Valves with ENVIRO‐SEALt packing systems will not require this initial re‐adjustment. See ENVIRO‐SEAL Packing
System for Rotary Valves Instruction Manual (D101643X012) for packing instructions. If you wish to convert your
present packing arrangement to ENVIRO‐SEAL packing, refer to the retrofit kits listed in the parts kit sub‐section on
page 19 of this manual.

Maintenance

Valve body parts are subject to normal wear and must be inspected regularly and replaced as necessary. The frequency
of inspection and replacement depends upon the severity of service conditions. Instructions are given in this section
for: replacing trim components, changing disk rotation or valve action, and mounting and adjusting the actuator.
As used in these instructions, actuator refers to power actuators (such as pneumatic diaphragm, piston actuators, and
rack and pinion actuators).
8
GE39986‐A
STANDARD PACKING
GE40118‐A
ENVIRO‐SEAL PACKING
THESE TWO SURFACES SHOULD REMAIN PARALLEL AS YOU ALTERNATELY AND EVENLY
3
TIGHTEN THE PACKING NUTS (KEY 28).
Instruction Manual
GRAPHITE RIBBON
GRAPHITE PACKING
D103302X012