CALIBRATING THE DISPENSER (Cont.)
LCD DISPLAY
C 4 r u n
MENU
(-)
C 4 1.0 8
MENU
(-)
C 6 2 0 0
MENU
(-)
C 7 E n g
MENU
(-)
- - -
C 8
MENU
(-)
- - -
C 9
MENU
(-)
L
C
x x
MENU
(-)
CALIBRATION MODE
Right (Decaf) Water Rate
(+)
Right (Decaf) Water Rate
(+)
Pump "OFF" Delay
(+)
English or Metric Mode
(+)
Error Code History
(+)
Reset Factory Defaults
(+)
(+)
DESCRIPTION
Set PRIME-NORMAL-RINSE switch to
RINSE position. Press and hold Decaf
Dispense Switch until flow stops (20
sec.) Refer to Field Calibration of the
Concentrate Pumps.
Enter Liters collected from the 20 sec.
test above.
Default = 1.08
Range = 0.95 - 1.12 Liters
Delays the Pump turn off after a
dispense.
Default = 200
Range = 1 - 999 mSec.
Eng for English
S.I. for Metric
Displays last known Error Code
Depress the Decrease (-) to view the
last 3 Errors.
Hold the Decrease (-) & Increase (+)
switches for 10 sec. to Erase.
Resets all set up values to the Factory
Default setting.
Hold both Increase (+) and Decrease
(-) switch for 10 seconds.
Displays Software Version # -
Exits To Home View After 3 Seconds.