Bunn LCA-2 LP Installation And Operating Manual page 14

Bunn lca-2 lp installation & operating manual
Hide thumbs Also See for LCA-2 LP:
Table of Contents

Advertisement

PROGRAMMING THE DISPENSER (Cont.)
Program Mode
: Used to change or enter new set-up values.
To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position, the unit will
display "__PPP" to indicate it is in the Program Mode. Use the MENU switch to scroll to the next display. Use
the Increase (+) and Decrease (-) switch to adjust the values.
LCD DISPLAY
P 1 1 8 0
MENU
(-)
P 2
3 0
MENU
(-)
P 3
3 0
MENU
(-)
P 4
0.
MENU
(-)
P 5
0.
MENU
(-)
P 6
0.
MENU
(-)
PROGRAM MODE
Tank Temperature
(+)
Left (Regular) Dispense Ratio
(+)
Right (Decaf) Dispense Ratio
(+)
0
Cup Dispense Volume
(+)
0
Carafe Dispense Volume
(+)
0
Left (Regular) Dispense Total
(+)
DESCRIPTION
Default = 180°F
Range = 120° - 200°F
Ready Temp = Tank Temp minus 10°F
Set Regular Coffee Ratio
Default = 30:1
Range = 25 Max / 100 Min
Set Decaf Coffee Ratio
Default = 30:1
Range = 25 Max / 100 Min
Set Cup Dispense Volume
Default = 0.0, Push & Hold
Range = 0.0 / 16.0 Oz.
Set Carafe Dispense Volume
Default = 0.0, Disabled
Range = 0.0 / 64.0 Oz.
Reset Total to Zero (00.0 Gal)
14
38791 072307

Advertisement

Table of Contents
loading

Table of Contents

Save Article as PDF