11.7 Horizontal Airflow Direction Control

The horizontal airflow direction louvers can be adjusted manually by hand.

11.8 Timer Control

11.8.1
To Set the Timer
To turn ON the unit at a preset time, set the timer while the unit is OFF (the operation will start 15 minutes early
before the preset time).
To turn OFF the unit at a delayed time, set the timer while the unit is ON.
Once the timer is set, the TIMER indication on the remote control display will be shown.
To check the remaining time before the timer takes effect, press
To cancel the timer, press
The timer will also be canceled when you press
This setting is for one time operation, you will need to set again each time you want to use the timer.
11.9

Random Auto Restart Control

If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when
the power is resumed.
It will start with previous operation mode and airflow direction.
If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to
operate will be decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed
and air swing louver position.
This Random Auto Restart Control is not available when Timer is set.
This control can be omitted by open the circuit of JX02 at indoor unit printed circuit board.
11.10

Remote Control Signal Receiving Sound

Short beep sound will be heard when turn ON the air conditioner or enabling other operations.
Long beep sound will be heard when turn OFF the air conditioner or disabling other operations.
once, then press again and hold for approximately 3 seconds.
or when power failure occurs.