Indoor Unit - Panasonic CS-YA18MKD Service Manual

Table of Contents

Advertisement

10.2 Indoor Unit

10.2.1
How to Fix Installation Plate
The mounting wall is strong and solid enough to prevent if from the vibration.
YA18***, YA24***
The centre of installation plate should be at more than  at right and left of the wall.
The distance from installation plate edge to ceiling should more than .
From installation plate left edge to unit's left side is .
From installation plate right edge to unit's right side is .
B
: For left side piping, piping connection for liquid should be about  from this line.
: For left side piping, piping connection for gas should be about  from this line.
1
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
o
a level gauge.
2
Drill the piping plate hole with ø70mm hole-core drill.
Putting measuring tape at position as shown in the diagram above.
o
The hole center is obtained by measuring the distance namely 128 mm for left and right hole
respectively. Another method is intersection point of arrow mark extension.
The meeting point of the extension arrow mark is the hole center position.
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
o
side. (refer to step 3)
10.2.2
To Drill a Hole in the Wall and
Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the busing to the sleeve.
3
Cut the sleeve until it extrudes about 15mm
from the wall.
4
Finish by sealing the sleeve with putty or
caulking compound at the final stage.
Model
1
585mm
Dimension
2
3
4
83mm
165mm
158mm
18
5
6
169mm
219mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-ya24mkdCu-ya18mkdCu-ya24mkd

Table of Contents