Maintenance Instructions
To facilitate maintenance, it is recommended that the fascia is removed. To do this, take off
the control knobs and remove 2 screws from the underside of the fascia panel.
Remove the nut from the underside of the griddle plate. The plate can then slide forwards
and be lifted off after withdrawing thermostat phials from underside of plate.
Thoroughly clean the burner and burner chamber.
Carefully clean the thermocouple probe, the ignitor, electrode and pilot jet.
Reconnect the gas supply and check for gas soundness.
Check that the flame safety device is operating by shielding the probe from the pilot flame
until the device operates.
Check that the spark ignites the gas.
Thoroughly clean the plate and fat chute, and drawer.
Replace the thermostat phial to its correct position and fasten the plate down to the body
by tightening the nut.
Refit fascia panel with the 2 screws and re-attach the control knobs.
Parry-British Built for Purpose