Fault-Finding; Operational Problems - Hardi MARRO TWIN FORCE 1000 Instruction Book

Table of Contents

Advertisement

F F F F F ault-f
ault-f
ault-f
inding
inding
ault-f
ault-finding
inding
inding
Opera a a a a tional pr
Oper
Oper
tional pr
tional pr
tional prob
ob
ob
oblems
Oper
Oper
tional pr
ob
In cases where breakdowns have occurred, the same factors always seem to come into play:
1. Minor leaks on the suction side of the pump will reduce the pump capacity or stop the suction completely.
2. A clogged suction filter will hinder or prevent suction so that the pump does not operate satisfactorily.
3. Clogged up pressure filters will result in increasing pressure at the pressure gauge but lower pressure at the
nozzles.
4. Foreign bodies stuck in the pump valves with the result that these cannot close tightly against the valve seat. This
reduces pump efficiency.
5. Poorly reassembled pumps, especially diaphragm covers, will allow the pump to suck air resulting in reduced or
no capacity.
6. Hydraulic components that are contaminated with dirt result in rapid wear to the hydraulic system.
Therefore ALWAYS check:
1.
Suction, pressure and nozzle filters are clean.
2.
Hoses for leaks and cracks, paying particular attention to suction hoses.
3.
Gaskets and O-rings are present and in good condition.
4.
Pressure gauge is in good working order. Correct dosage depends on it.
5.
Operating unit functions properly. Use clean water to check.
6.
Hydraulic components are maintained clean.
52
lems
lems
lems
lems
GB 16 04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Marro twin force 1300

Table of Contents