Limit Thermostat - Bunn CWA-APS Operating & Service Manual

Cwa-aps, cwa-ts, cwta-aps, cwta-ts operating & service manual
Hide thumbs Also See for CWA-APS:
Table of Contents

Advertisement

SERVICE (cont.)
LIMIT THERMOSTAT (CWTA & CWTFA)
FIG. 4 LIMIT THERMOSTAT
Location:
The limit thermostat is located inside the rear of
the hood on the tank lid.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the blue and black wires from the limit
thermostat.
3. With an ohmmeter, check for continuity across the
limit thermostat terminals.
If continuity is present as described, the limit thermo-
stat is operating properly.
If continuity is not present as described, replace the

limit thermostat.

Removal and Replacement:
1. Remove all wires from limit thermostat terminals.
2. Carefully slide the limit thermostat out from under
the retaining clip and remove limit thermostat.
3. Carefully slide the new limit thermostat into the
retaining clip.
4. Refer to Fig. 5 when reconnecting the wires.
P2195.40
BLK to Tank
Heater Switch
FIG. 5 LIMIT THERMOSTAT TERMINALS
Page 15
BLU to BLU Lead
from
Control Thermostat
P1800
10690.1 063000

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

TsCwa-tsCwta-apsCwta-tsCwa-atsCwta-ats

Table of Contents