Bunn CWA-APS Operating & Service Manual page 12

Cwa-aps, cwa-ts, cwta-aps, cwta-ts operating & service manual
Hide thumbs Also See for CWA-APS:
Table of Contents

Advertisement

TROUBLESHOOTING (cont.)
PROBLEM
Weak beverage (cont.)
Dry coffee grounds remain in the
funnel
Brewer is making unusal noises
Brewer is making unusal noises
(CW)
PROBABLE CAUSE
5. Water Temperature
1. Funnel Loading
1. Solenoid (CWTA-APS, CWTFA-
APS, CWTA-TS & CWTFA-TS)
2. Plumbing Lines
3. Water Supply
4. Tank Heater
1. Tank Heater
Page 12
REMEDY
Place an empty funnel on an empty
dispenser beneath the sprayhead.
Initiate a brew cycle and check the
water temperature immediately
below the sprayhead with a ther-
mometer. The reading should not
be less than 195°F (91°C). Adjust
the control thermostat to increase
the water temperature. Replace if
necessary.
The BUNN® paper filter must be
centered in the funnel and the bed
of grounds leveled by gently shak-
ing.
The nut on the solenoid must be
tight or it will vibrate during op-
eration.
Plumbing lines should not resting
on the counter top.
(A) The brewer must be connected
to a cold water line.
(B) Water pressure to the brewer
must not exceed 90 psi (620 kPa).
Install a regulator if necessary to
lower the working pressure to ap-
proximately 50 psi (345 kPa).
Remove and clean lime off the
tank heater. See page 19
Remove and clean lime off the
tank heater. See page 19
10690.1 063000