NAPCO iSecure Installation & Programming Instructions page 35

Professional cellular alarm system
Table of Contents

Advertisement

12. Install Takeover Module (cont'd)
P2
1 2 3 4 5 6
EARTH
GROUND
EARTH
16VAC SUPV
JUMPER:
EOLR
2.2K
Wiring example of a burglary
device; in this example, a
wired door / window contact
Napco iSecure Security System
See JUMPER DESCRIPTIONS,
Jumper Block P2 on page 34.
1 - Shunt to factory DEFAULT flash
memory (enters RF LEARN mode).
2 - Shunt to DISABLE AC monitoring.
3 - Shunt to DISABLE BATTERY
FIRE
monitoring.
CO
4 - Reserved.
BURG
5 - Reserved.
6 - Shunt to start an END OF LINE
RESISTOR LEARN process for
zone terminals Z1 through Z8.
+12V GND
Z1+
Z2+ GND
Z3+
Z4+ GND
SET
FIRE
CO
BURG
All technical manuals are available in PDF format at
ISEC-WL-MODULE
Wiring Diagram
Z5+
Z6+ GND
Z7+
Z8+ GND
F PWR
SET
JUMPER:
FIRE
CO
BURG
EOLR
2.2K
POWER
*If the power to the CO
IN*
detector requires monitoring,
use a power monitoring relay
(–) (+)
or other approved device.
Wiring example of a
Carbon Monoxide
Detector
2.2KΩ
(–)
BLACK
BATT+ PNL+
SET
JUMPER:
OPTIONAL
THERMOSTAT
FIRE
CO
BURG
Wiring example of a
Conventional 4-Wire
Smoke Detector
tech.napcosecurity.com
12-18VAC
TRANSFORMER
Control panel power or
auxiliary power supply
(+)
12VDC
RED
Back Up
Battery used by
Battery
the control
panel to be
"taken over"
(–) (+)
FIRE
ZONE
POWER
IN
IN
FIRE
POWER
ZONE
OUT
OUT
(–) (+)
4 WIRE
SMOKE
DETECTOR
(E)
EOLR (part #
2.2K
FT2200)
35