Installing your dishwasher

Draining away the waste water

Length of the drain hose: standard
1.50m. If necessary, you can
increase the length of the drain
hose (4m max.). In this case, check
that the machine drains correctly.
Connect the drain hose:
- To a ventilated siphon
- To a sink U-bend
Remove the stopper form the
U-bend.
Remove the rubber stopper and, if
necessary, add a collar.
- Directly to your sink.
Ensure that you hold your drain
hose
in
place
with
the
connector to avoid flooding.
20
For machines installed in columns,
the height of the drain hose must
not be higher than the top of the
machine.
NB: Pull the pipe
gradually when
installing it to avoid
kinking it.

Electrical connection

Mains voltage: 230V
Fuse: 10A, 13A or 16A
The
socket
outlet
must
grounded to Earth.
In all cases, the connection must
comply with the standards in force
in the country concerned, together
with the supplementary regulations
of the Electricity Authority. The
machine must be switched off when
the connection is made to the
electrical circuit.
We cannot be held
liable for any damage
caused by the faulty earthing
of the machine.
If you have any doubts regarding
the condition of your installation, do
not hesitate to have it checked by a
end
qualified electrician.
The machine must be installed so
that the socket remains accessible.
GB
Installing your dishwasher
Do not use an electrical extension,
a double socket or an electrical
timer. The installation must comply
with the country's prevailing norms.
Your dishwasher complies with
European
Directives
(Low
Voltage
89/336/EEC
Compatibility),
Directive 93/68/EEC.
be
IMPORTANT for the dishwasher without plug.
The wires in this mains lead ar coloured in accordance the
following code :
Green & Yellow
Blue
Brown
As the colours of the wires in the mains lead of this appliance may not
correspond with the terminal in your plug, proceed as follows ; The wire
which is coloured Green and Yellow must be connected to the terminal
which is marked with the letter «E» or by the earth symbol
coloured Green end Yellow.
The wire which is coloured Blue must be connected to the terminal
which is marked with the letter «N» or coloured Black.
The wire which is coloured Brown must be connected to the terminal
which is marked with the letter «L» or coloured Red.
Replacing the power
cable
For your safety, this operation
must be performed by the
manufacturer's
department or a person with
similar training and experience
in order to avoid any risk.
73/23/EEC
Directive)
and
(Electromagnetic
modified
by
Earth
Neutral
Live
GB
After-Sales
or
21