Download Print this page

Nokia 3310 Manual page 25

Hide thumbs Also See for 3310:

Advertisement

Customer Care Europe, Middle East & Africa
SCCE Training Group
CHAPTER 7:NOT CHARGING
Battery temperature failed
Check X203,
R220/222, change
N201
© NMP 2002
Nothing happens if
charger is connected
voltage level at R210,
0.8 V if charger is
Change N200, N201
"Not charging"
appears on LCD
Run energy
management
FAILURE MESSAGES
Battery size failed
Battery voltage failed
Check X203,
Change N201
R221/222, change
N201
CONFIDENTIAL
NHM—2/5/6
3410
Date 20.11.2002
Flowchart 7-1
Check
Check/change X200,
nOK
F200, V201, L202
and C215-217
connected
OK
Try to charge after
OK
calibration
calibration
Charge current failed
Check R204, change
N200, N201
Checked by:
Customer Care E&A
25 (44)
Repairhints
Version 4.0 Approved
Charge voltage failed
Check Vcharge
at voltage divider
nOK
R209/210, 0.8 VDC
with ACP-7
OK
Change N201
Check X200,F200,V201,
L202,C215-217, change
N200
Approved by:
SCCE Training Group

Advertisement

loading

This manual is also suitable for:

3303410