Rohnson R-9424 User Manual

Rohnson R-9424 User Manual

With r290 refrigerant

Advertisement

Quick Links

Home Dehumidifier
User Manual
Original instructions
R-9424
(With R290 refrigerant)
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R-9424 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rohnson R-9424

  • Page 1 Home Dehumidifier User Manual Original instructions R-9424 (With R290 refrigerant)
  • Page 2: Table Of Contents

    CONTENT 1. BEFORE YOU BEGIN ..............................3 1.1 PRODUCT DESCRIPTION ........................... 3 1.2SYMBOLS FROM THE UNIT AND USER MANUAL ..................... 3 2. FOR YOUR SAFETY ................................ 5 OPERATIONALPRECAUTIONS........................5 2.2 SAFETY PRECAUTIONS ON SERVICING ......................7 2.2.1 Checks to the area ..........................7 2.2.2 Work procedure ............................
  • Page 3 8. TROUBLESHOOTING ..............................18 9. SAFETY WARNING ............................... 19...
  • Page 4: Before You Begin

    1. BEFORE YOU BEGIN 1.1 PRODUCT DESCRIPTION The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in relative humidity protects buildings and their contents from the adverse effects of excess humidity. The environmentally friendly R290 is used as the refrigerant. R290 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide.
  • Page 5 THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY ⚫ This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. ⚫ This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6 or in the vicinity of the units. ⚫ Component parts are designed for propane and non-incentive and non-sparking. Component parts shall only be replaced with identical repair parts. FAILURE TO ABIDE BY THIS WARNING COULDRESULT IN AN EXPLOSION, DEATH, INJURY ANDPROPERTY DAMAGE.
  • Page 7: For Your Safety

    2. FOR YOUR SAFETY Your safety is the most important thing we concerned! Please read this manual carefully and fully understand before operating your dehumidifier. WARNING OPERATIONALPRECAUTIONS WARNING- to reduce the risk of fire, electric shock or injury to persons or property: ◼...
  • Page 8 Do not operate the unit if it is dropped, damaged or showing signs of product malfunction. ◼ ◼ Do not clean the appliance with any chemicals. ◼ Ensure the unit is far away from fire, inflammable, or explosive objects. ◼ The unit shall be installed in accordance with national wiring regulations. ◼...
  • Page 9: Safety Precautions On Servicing

    2.2 SAFETY PRECAUTIONS ON SERVICING Please follow these warnings when to undertake the following when servicing a dehumidifier with R290. 2.2.1 Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
  • Page 10: Checks To The Refrigeration Equipment

    the work is carried out. The ventilation should safely disperse any released refrigerantand preferably expel it externally into the atmosphere. 2.2.8 Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification.
  • Page 11: Installation

    3. INSTALLATION 3.1 LOCATION Place the unit on a firm, level surface in an area with at least 30cm of free space around it allow for proper air circulation. Never install the unit where it could be subject to: Heat sources such as radiators, heat registers, stoves or other products that products ➢...
  • Page 12 Install the unit in rooms which exceed4 m². Do not install the unit in a place where inflammable gas may leak. WARNING! The manufacturer may provide other suitable example or may provide additional information about the refrigerant odour. NOTE!
  • Page 13: Operating The Device Safely

    3.2 OPERATING THE DEVICE SAFELY Check the device after unpacking for any damages or scratches on it. ⚫ Operate this unit in an ambient temperature from 5°C to 35°C. ⚫ Do not use outdoors. This dehumidifier is intended for indoor residential applications only. ⚫...
  • Page 14: Product Overview

    4. PRODUCT OVERVIEW FRONT VIEW Control Panel Air Outlet Front Cover Caster BACK VIEW Filter Frame Continuous Drain Plug Back Cover Water Tank...
  • Page 15: Features

    ✓ Electronic control/Auto shut-off/ auto restart Effectively removes moisture, dust, and dust mites from the air. ✓ ✓ 1-24 hour timer to set the time of operation. 4.3 SPECIFICATIONS MODEL R-9424 24L/day (30℃, 80%RH) Rated Capacity Power supply AC220-240V/50Hz Power Consumption 280W/1.25A (30℃, 80%RH)
  • Page 16: Operation

    5. OPERATION 5.1 CONTROL PANEL FUNCTION KEYS AND INDICATORS POWER button Press to switch the machine on or off. Sleep/Reset button Press to turn sleep mode on or off. Hold this button to reset the filter Timer button Sets a time for the unit to automatically start or stop. Fan speed button Press to select fan speed between high and low.
  • Page 17: Settings

    Low Speed Light Lights up when switch to Low speed. Drying mode Lights up when switch to Continuous Drying mode AUTO mode LED Lights up when switch to AUTO mode. Digital Display Displays humidity value, Timer setting or Temperature. 5.2 SETTINGS Power button Press POWER key to switch the machine on and off.
  • Page 18: Settings Indicator Light

    Speed button The fan speed can only be adjusted in automatic mode. Mode button Press the mode key to switch between automatic and dry mode. Automatic mode: adjustable humidity, adjustable fan speed. Drying mode: The compressor keep working without controlling by humidity; Fan works in high speed (fan speed and humidity are not adjustable).
  • Page 19 Wind speed indicator light When you set the wind speed to low, the low wind indicator lights up. When you set the wind speed to high, the high wind indicator lights up. Child-lock indicator light Turn on child-lock mode, the child-lock indicator light is on. Water full indicator light When the water tank is full with water, the indicator light up and there is an alarm sound to remind the user that the water is full.
  • Page 20 6.1 Empty the water tank ⚫ Do not remove the float out of the tank. Make sure that the float can move freely and that it will actuate the level switch when the tank is full. ⚫ Allow the tank to air-dry completely and slide it back into place within the dehumidifier.
  • Page 21 6.2CONTINUOUS DRAINAGE Condensate water can be automatically flow into a bucket or drain by gravity with a water hose. • First pull the water plug head out of the drain hole • Rotate 180" down to avoid the drain hole. Inner •...
  • Page 22: Maintenance

    6. MAINTENANCE Dehumidifier cleaning Body cleaning: Use a soft and slightly moist cloth to clean the dehumidifier body. Filter cleaning: 1. Remove the screen frame from the back cover and gently absorb the dust on the screen frame surface with a vacuum cleaner. 2.
  • Page 23 7. TROUBLESHOOTING The conditions machine compressor starting and stopping When the ambient temperature <5℃, the ambient temperature > 35℃, the temperature and humidity sensor fault, the compressor does not work; During defrosting, the compressor does not work and the fan still works. If the following situation occurs, please confirm the following situation before consulting the customer service: FAULT DESCRIPTION...
  • Page 24 compressor will stop immediately, and the fan will stop in time. When the ambient humidity is <20RH, this code will appear, the the screen show “LO” compressor will stop immediately, and the fan will stop in time. When the ambient humidity is >90RH,at this time the compressor/fan the screen show “HI”...
  • Page 25 IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002/96/EC. At the end of its working life, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection centre or to a dealer providing this service.

Table of Contents