Advertisement

ULTRA-1
ULTRA-2
PROGRAMMING MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
41047.0000C 07/09 ©2008 Bunn-O-Matic Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Bunn Ultra-1

  • Page 1 ULTRA-1 ULTRA-2 PROGRAMMING MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 41047.0000C 07/09 ©2008 Bunn-O-Matic Corporation...
  • Page 2 SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
  • Page 3: Table Of Contents

    INTRODUCTION This equipment dispenses granita-type and cold liquid drinks on demand from separate hoppers. Operating controls are accessible only through password protection. CONTENTS Introduction & Warranty....................... 3 Operating Controls ....................... 8 Programming ........................6 Switches ........................6 Programming the Dispenser ..................7 Function Index .......................
  • Page 4: Operating Controls

    OPERATING CONTROLS ULTRA-1 There are three of these switches that will be used for the operation of the dispenser. P3932 switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming.
  • Page 5 OPERATING CONTROLS ULTRA-2 There are five of these switches that will be used for the operation of the dispenser. P3677 switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming.
  • Page 6: Programming

    Access to most controls can be password protected to allow only qualified personnel to make changes. P3931 P3677 ULTRA-1 ULTRA-2 PROGRAMMING SWITCHES To access the programming mode, and to scroll through the different function screens, hidden programming switches are used.
  • Page 7: Programming The Dispenser

    PROGRAMMING THE DISPENSER During normal operations, the Date, the Time, and the Serial Number toggle back and forth continuously. The following function screens are in the order they appear from the menu display. Each screen will have instructions and procedures to program the various functions of the dispenser. HOME SCREEN Displays the TIME, DATE, SERIAL NUMBER and ASSET NUMBER which toggle back and forth continuously.
  • Page 8 MENU FUNCTION INDEX (Continued) SET THICKNESS ? TEST AUGERS ? CLEANING GUIDE ? SET LANGUAGE ? PASSWORD 0 SET DATE TIME ? NEXT PM COMPLETE ? DEFROST MINUTES SET NIGHT TIME YES THICK ADJUST DAY TO CLEAN OFF 6 MONTH PM NEXT NEXT 250 L REFILL 155...
  • Page 9: Cleaning Guide

    Cleaning Guide This function leads the operator through a nine step cleaning process when answered YES (“ICE”). Depress GOURMET to display the next cleaning instruction. When entering this mode, the refrigeration system will automatically turn OFF. After step when hoppers are drained, the augers will turn OFF.
  • Page 10: Set Consistency

    (“ICE”). Two screens will appear for left and right. The operator can scroll through a range of a minimum of 1 (ULTRA) to a maximum of 16 (ICE). Factory default is 10. NOTE: ULTRA-1 models will only have one adjustment screen. SET THICKNESS ?
  • Page 11: Test Augers

    NEXT REVERSE Select NEXT to repeat process for Right Auger Test. NOTE: ULTRA-1 models will only have one test screen. Set Time and Date Selecting YES (ICE) allows the operator to set the DATE (YY MM DD) and TIME (HR MIN SEC) for display on the Home Screen.
  • Page 12: Password

    Password From this screen, the operator must know the password before moving on to the remaining functions. The range is from 0 - 9999 with the factory default being 0. PASSWORD NEXT P3678 Set Language ? (Late Model Dispensers) The setting of the Set Language mode allows the operator to scroll thru a list of languages stored in the software and select one for the display messages.
  • Page 13: Set Night/Day Time

    Set Night Time/Set Day Time The setting of the Day/Night mode allows the dispenser to “power down” during off hours. The bottom corners displaying “ICE” will change to “CHILL” during the night mode. During the night mode, the product will be kept chilled to below 35°F.
  • Page 14: Preventive Maintenance

    Preventive Maintenance Complete? This function is used to reset a reminder message Preventive Maintenance Due every six months. The machine will not shut down if service is not performed. When the service is performed and the message is answered YES (ICE), the time and date is recorded for another six months to elapse.
  • Page 15: Days To Clean 14

    Day To Clean Off This function allows the operator to program a cleaning schedule from 1 to 14 days. The default screen is 0 or OFF. Selecting - or ULTRA will prompt the screen Days To Clean. Once a number of days is selected the screen will prompt two functions, CLEAN MESSAGE ONLY or CLEAN LOCKOUT.
  • Page 16: Consistency Adjust Lock

    Consistency Adjust Lock This is an option of locking the Set Consistency function by selecting + (YES) or - (NO). NO THICK ADJUST YES THICK ADJUST NEXT NEXT Switches Enabled This function allows the operator to lockout the touch pad. Selecting + (ON) provides no time delay on switches except for the center (GOURMET) hidden switch.
  • Page 17: Delayed Refill

    Delayed Refill (Late Model ULTRA 2 Dispensers with Refill Kit Installed only) This function allows the operator to dose in small amounts of new product while delaying between doses. This can help the already frozen product from becoming deluted and not ready to serve. These delay and fill times are to be determined and set based on each application as desired by the end user.
  • Page 18: Refill Threshold

    250 R REFILL 155 (-) THRESHOLD (+) (-) THRESHOLD (+) TEST REFILL ? ACTIVATE VALVE LEFT DONE RIGHT ULTRA-1 Models only: This function will activate the Liquid Autofill function only in machines equipped with this option. ENABLE REFILL ? 41047 040108...
  • Page 19: Ad Message Enabled

    Ad Messages Enabled (Late Model Dispensers) This function allows the operator to create an AD Message that will toggle with the Home Screen mes- sages. AD MESSAGE AD MESSAGE DISABLED ENABLED MODIFY MESSAGE ? SCROL THRU ALPHA (MESSAGE) NEXT-NEXT LETTER SCROL DONE NEXT SAVE ? AD MESSAGE...
  • Page 20: Enter Asset Number

    Enter Asset Number This is the function to set the asset number using a range of 0 to 999999 (the factory default is 0). It is used to track the usage or service of an individual machine within a group. ENTER ASSET # AN000000 Set Password...
  • Page 21: Restore Defaults

    Restore Default? Answering YES (ICE) to this function returns the unit back to preset factory constants. 1. Set Consistency ? 8 2. Set Night Time - DISABLED RESTORE DEFAULT ? 3. Set Day Time - DISABLED 4. 6 Month PM - ON 5.
  • Page 22: Temperature & Torque

    Press and release the ULTRA and ICE hidden switches to return to HOME SCREEN. The TEMP & TORQUE mode is typically used for service. DISPLAY TEMP & TORQUE 67°h 36° NOTE: ULTRA-1 models will display Barrel Temperature and Torque readings on the left side of the display. 41047 040108...

This manual is also suitable for:

Ultra-2

Table of Contents