All the devices of this system are equipped with a specialized grounding screw, marked with the
icon
. After installing in the cabinet, cabinet grounding and device grounding should be
connected by a soft cable with a cross-section of 1.5mm
Caution:
To prevent a grounding loop, be careful to not let a short circuit occur over the grounding wires.
During the installation of amplifier, to ensure a better cooling performance, 1U blind plate is
recommended between the amplifier and device.
Before installation, inner space of the cabinet should be arranged based on the actual number and
types of devices. The bottom plate needs to be installed, and the empty spaces can be filled with
blind disk.
The X-618 spare list includes foot for the bottom of the device, which is used for desktop
installation. Make sure there is no foot installed at the bottom of the device before installation.

Installing the Devices in the Appliance Cabinet

Installing the DCS, NRI and DA into the associated appliance cabinet
Installing the DCS, NRI and DA into the cabinet is done as follows:
1.
Install brackets on the left and right sides of the DCS, as shown in Figure 5.
Figure 4 Schematic Diagram of Cabinet Grounding
Figure 5 Schematic Diagram of the DCS Bracket Installation
2.
13