Honeywell X-618 Installation Manual page 31

Public address system
Hide thumbs Also See for X-618:
Table of Contents

Advertisement

1.
Strip off the wire jacket of one end of the prepared audio cable by about 10mm, insert into the
loudspeaker wiring terminal, and tighten the screws.
2.
Insert the loudspeaker wiring terminal of the installed audio cable into the DCS loudspeaker
port.
3.
Connect the loudspeaker to the other end of the audio cable, and if there are many speakers
in the same line, please follow the connection method shown in Figure 22.
Figure 22 Schematic Diagram of the Loudspeaker and the Audio Cable Connection
Connecting the DCS and NRI to the NPM
In the X-618 system, the DCS, the NRI and the NPM form a complete system through the Ethernet.
The DCS and NRI can be connected to the NPM in the following two ways:
Directly connecting the DCS and NRI to the NPM
Connecting the DCS and NRI to the NPM through a network switch
Directly Connecting the DCS and NRI to the NPM
Use twisted pair cables to connect the network ports of the DCS, the NRI and the NPM.
Insert one end of the prepared twisted-pair cable into the network port located on the rear panel of
the DCS, and the other end of the cable into the RJ45 port located on the rear panel of the NPM,
and connect the network port of DCS to the NRI's network port using another twisted-pair cable.
Connecting the DCS and the NRI to the NPM through a Network Switch
Connect the DCS and the NRI to the NPM through a network switch. The DCS and network switch
must be on the same network. Refer to Figure 23.