40 | WBE 4200 | Menu navigation
5.

Menu navigation

We can divide the balancing machine menu in several
submenus:
$

Configuration of the use

$

Configuration of the board

$
Calibration
$
Auto-diagnosis
Access to the main menu is gained by pressing the
<MENU> key and, by keeping the <MENU> key pressed,
the various entries under the submenus are scrolled.
To confirm access to the menu, press the <USER> key
within 1.5 seconds.
5.1
Configuration of the use
Press the <MENU> key to the writing SET.
i
You can access the sub-menu by releasing the
<MENU> key.
R
<MENU> - SET
"
Using <MENU>, you can surf the menu
"
To exit press <SPLIT>.
Left display
Right display
TOL
Current value
in grams /
ounces
RES
1
5
or
UMB
GRA
OUN
SND
ON
OFF
CAR
ON
OFF
LAR
0.50
1)
0.25
|
1 695 600 091
2012-11-16
Description
Entry of balance weight value
below which the value "0" is to
be displayed.
Standard value 4.5 g (0,25 oz),
maximum value 25 g (1,25 oz)
5
0.25
g /
oz - Standard
resolution
1
0.05
g /
oz - Fine resolution
GRA =
Display in grams
OUN =
Display in ounces
ON =
An acoustic signal
sounds on storing the data
determined
OFF =
No acoustic signal
sounds on storing the data
determined
ON =
Start of measurement
by closing wheel guard
OFF =
Start of measurement
START
by pressing <
> key
(with wheel guard
closed)
0.50
= Entry of rim width in
0.5 inch increments
0.25
= Entry of rim width in
0.25 inch increments
ALU
P G
P 3, P 6, P12
ATA
ON
OFF
1) Function only available with gauge arm for measuring rim width
fitted and activated.
NOTES FOR THE ASSISTANCE:
Here you are the settings belonging to the WBE 4200
version:
Left Display
TOL
RES
UNB
SND
CAR
ALU
ATA
Tab. 3:
Settings for WBE 4200
5.2
Configuration of the board
To enter the use configuration menu, press <MENU>
until the notice TOL will appear on the left display and
after 1.5s max, press <OPERATOR>. Finally, in order
to change values use + and –. To confirm, press <RIM
DISTANCE>.
R
<MENU> - SET - TOL
"
Using <MENU>, you can surf the menu
"
To exit press <SPLIT>.
Left display
Right display
POT
On
OFF
ALU
On
OFF
FLA*
On
OFF
PLR
On
1)
OFF
R Positioning of adhesive
weight for ALU2, ALU3 and
PAX2:
Setting PG
$
:
Attachment with Easyfit®;
Setting P3, P6 or
$
P12:
With manual vernier cali-
per or without tools:
Attachment in 12, 3 or 6
o'clock position.
R With all other programs and
for all adhesive weights the
balance weight must be
attached in the 12 o'clock
position.
ON = activates the automatic
balancing program recognition
function.
OFF = does not activate the
automatic balancing program
recognition function.
Right Display
5
5
GRA
On
On
PG
On
Description
Turn on/off the internal
automatic gauge
Turn on/off the gauge function
called "ALUDATA®"
Activate/Disactivate
measurement acquisition with
automatic calipers by pressing
the pneumatic flange pedal
Turn on/off the width gauge