Download Print this page

Husqvarna QHFB860P User Manual page 4

Advertisement

Available languages
  • EN

Available languages

Pa (4 x 10
bar). This manual must be
●5
stored for future consultation at any time.
If sold, transferred or moved, it must
remain with the device.
Caution! Failure to install screws and
fasteners in accordance with these
instructions may result in electrical
hazards.
Both
electric
installation must be carried out by
specialised personnel.
The electrical appliance is designed to be
built into a work top with a thickness of 2-
6 cm in the case of TOP installation; 2.5-
6 cm in the case of FLUSH installation.
The minimum distance between the hob
and the wall must be at least 5 cm in
front, at least 4 cm on the sides and at
least 50 cm from overhead wall units.
NB = The recommended distances are
given as examples: when planning the
spaces, the indications of the kitchen
manufacturer must be observed.
Electrical connection: Fig. 3
● Disconnect the device from the electric
power supply. ● Installation must be
carried out by professionally qualified
personnel
with
regulations in force for installation and
safety. ● The manufacturer denies all
liability to persons, animals or property if
the guidelines provided in this chapter
are not followed. ● The power cable
must be long enough to allow the hob to
be removed from the worktop. ● Make
sure that the voltage on the serial
number data plate on the bottom of the
device corresponds to that of the
domestic environment where it will be
installed. ● Do not use extension leads.
● The earth power cable must be 2cm
longer than the other cables. ● If the
electrical appliance is not supplied with a
power cable, use one with a minimum
and
mechanical
knowledge
of
conductor diameter of 2.5 mm2 for power
up to 7200 Watt; for higher power levels,
the diameter must be 4 mm2. ● The
temperature must not reach 50°C above
room temperature anywhere along the
cable. ● The appliance is intended for
permanent connection to the power
supply.
Note: to connect the appliance using the
optional single phase connection the
existing cable must be removed and
replaced with another type (not supplied)
having the following specifications:
single phase connection:H05V2V2-F 3G4
cable Fig. 3a
● Please note! Before reconnecting the
circuit to the mains power supply, make
sure that it is working correctly, always
check that the power cable is correctly
installed.
interconnection cable must be replaced
by the authorised technical support
service or by a person with similar
qualifications.
Note : the product is equipped with a
Power Limitator function, which allows a
maximum power limit to be set
The limit must be set at the time of the
the
product's connection to the electrical
network or when the electrical network
itself is reconnected (within the following
2 minutes). For the Power Limitation
setting sequence, see the Operation
section of this manual.
This device is marked in compliance with the European
Directive 2012/19/EC - UK SI 2013 No3113, Waste Electrical
and Electronic Equipment (WEEE). By ensuring that this
device is disposed of correctly, the user will help prevent
potential negative impacts on the environment and human
health.
The
symbol on the device or documentation provided
indicates that this device must not be treated as domestic
waste, but must be taken to a suitable waste collection site for
the recycling of electrical and electronic appliances. Dispose
3