Energy Saving - Ricoh GR-C1 Series Service Training

Hide thumbs Also See for GR-C1 Series:
Table of Contents

Advertisement

2.2 Overview – 2 (System Settings)
Power
Consumption
Plug In
1) Timer settings and recovery time (System settings => Timer setting)
Mode
Off/Sleep Mode
Slide 214
The user can set these timers with User Tools
MFP/ Priport: User Tools > System settings > Timer Setting
Printer
Normally, Panel Off timer < Energy Saver timer < Auto Off timer.
But, for example, if Auto Off timer < or = Panel Off timer and Energy Saver timer,
the machine goes immediately to Off mode when the Auto Off timer expires. It
skips the Panel Off and Energy Saver modes.
Example
Panel off: 1 minute Low power: 15 minutes, Auto Off: 1 minute
The machine goes to Off mode after 1 minute. Panel Off and Low Power
modes are not used.
We recommend that the default settings should be kept.
If the customer requests that these settings should be changed, please
explain that their energy costs could increase, and that they should
consider the effects on the environment of extra energy use.
If it is necessary to change the settings, please try to make sure that the
Auto Off timer is not too long. Try with a shorter setting first, such as 30
minutes, then go to a longer one (such as 60 minutes) if the customer is not
satisfied.
If the timers are all set to the maximum value, the machine will not begin
saving energy until 240 minutes has expired after the last job. This means
that after the customer has finished using the machine for the day, energy
will be consumed that could otherwise be saved.
If you change the settings, the energy consumed can be measured using
SP8941, as explained later in this presentation.
Power consumption during warm-up may be much higher than shown in this
diagram.

2. Energy Saving

Warm-up Operation Mode
Ready Mode
Off/Sleep Mode
Auto Off Timer
Timer Starts
1 – 240 min
Timer
Default
Auto Off Timer
1 min.
: User Tools > System settings > Energy Saver Timer
214
Time
After 240 min
from last job
Setting range
Recovery time
1 to 240 min.
10 sec.