Warning
All purchasers, installers and users shall read the instructions and data plate carefully before installation,
operation, use or servicing of the gas heater. Not following these instructions can result in death, serious injury,
fire or property damage. In that case all responsibility of any accident whatsoever in connection with the
purchase, installation, operation, using and servicing of the gas heater and accessories will be rejected. Keep
this manual for future reference.
Safety advice
The gas heater and accessories shall be installed and tested on site by a qualified, competent and
approved gas installer, according this manual and according all applicable local and national regulations.
The gas heater is designed for the brooding of selected livestock, like: chickens, piglets, game birds, ducks,
etc. within livestock rearing housing, or for local heating projects outside, or in workshops or other industrial
environment. It is not designed for any other heating applications. Do not use it inside habitable parts of
buildings and houses or for domestic use.
All air inlets in the livestock house shall be inspected and checked regularly to be clear of dust, dirt and any
foreign material to allow the free flow of fresh air into the building.
For safe operation a fresh air supply to the heater of at least 20 m³/h per 1 kW installed heat input is needed.
Note that in most situations animals need much more fresh air. A well ventilated area is very important for
safe operation of a gas heater. Follow in non-agricultural situations the requirements of EN13410.
Use only gas cylinders with a gas isolation valve or gas lines with a main gas valve at the beginning. In
case more than one heater is connected to a gas system, place also a gas tap directly before the heaters.
Close these taps when the heaters are not in use.
Do not use the heater in areas where gasoline or flammable liquids or gases may be present. Also keep a
safe distance to other easy inflammable materials like curtains, etc.
Do not touch, move, handle or service the gas heater while it is burning.
Version: jan 2011
Alke 21, 41, 61, 81, 3000
(Versions: -SKTE, -SKTETH, -SKTETHi)
Manufacturer:
Alke BV
Industrielaan 11a
3925 BD Scherpenzeel
POBox 52
3925 ZH Scherpenzeel
The Netherlands
Tel: +31 33 277 3824
Fax: +31 33 277 3080
Email: info@alke.nl
61, 81, 3000
1
Manual number: 0009 0520EN

Advertisement

loading
Need help?

Need help?

Do you have a question about the 21 and is the answer not in the manual?

Questions and answers

Summary of Contents for Alke 21

  • Page 1 User and Installation Manual Alke 21, 41, 61, 81, 3000 (Versions: -SKTE, -SKTETH, -SKTETHi) 21, 41 61, 81, 3000 Manufacturer: Alke BV Industrielaan 11a 3925 BD Scherpenzeel POBox 52 3925 ZH Scherpenzeel The Netherlands Tel: +31 33 277 3824 Fax: +31 33 277 3080 Email: info@alke.nl...
  • Page 2  Before doing any maintenance, installation or service, first close the gas supply and wait till the gas heater has cooled down.  Propane gas and natural gas are very flammable and are scented with a strong smell. If any gas smell is noticed, immediately turn off the gas supply.
  • Page 3 Keep always a safe distance around the gas heater to other materials and walls. See the table below for the minimum safety distances. The operational distances are guidelines to start with. Adjust later on to the correct height based on your personal preference and experience. For non-agricultural installations keep a distance of at least 2,0 meters from floor to the heater.
  • Page 4 The most common way to install a gas line is in the centre of the barn (at least 2 meter high) with every 3 to 5 meter a “T” or “cross” connection for gas supply to the heaters. Always mount a (easy reachable) gas tap at the beginning of the gas hose to the heaters.
  • Page 5 Maintenance The frequency of maintenance is strongly depending on the quality of the combustion air and the intensity of use. When used in poultry houses, maintenance is advised every 6 weeks or by changing the animals. By use in clean environment conditions, the maintenance period can be extended, but not longer than 6 months. In case heaters are not used for a long period, always do maintenance first before using them again.
  • Page 6 Injector (12) partly blocked Declaration of conformity We, Alke B.V., located in Scherpenzeel, The Netherlands, hereby declare that the 21, 41, 61 and 81 series, marked on their data plates with CE and with the CE approval/production supervision number 0063 of Kiwa...
  • Page 7 Parts list The parts list below is a combination list of all 21, 41, 61 and 81 models. Most parts of these models are identical. Consult the data plate to determine the model you have before using this list. 81/3000...
  • Page 8 Heat Input hole Injector (TE)/(TH) Holder (mbar) (mbar) (kW Hs) (kW Hs) (g/h or m3/h) (mm) (mm) (mm) (kg) 21 series 0,11 m3/h 0,76 2,6/2,9 I2H, I2E 0,10 m3/h 0,76 2,6/2,9 I2E+ G20/G25 20/25 I2ELL (LL) 0,13 m3/h 0,71 2,6/2,9...

This manual is also suitable for:

4161813000