Eexd Cable Screwed Joints - Bosch Rexroth MKE035B-144 Project Planning Manual

Synchronous motors for potentially hazardous areas
Table of Contents

Advertisement

EExd cable screwed joints

DOK-MOTOR*-MKE*******-PRJ1-EN-E1,44 • 06.97
To meet the explosion requirements, it is necessary to tighten the cable
screwed joints after power and feedback cables are in place.
Tightening torque: 15 Nm
A tightening torque of approximately 15 Nm is achieved if the cable scre-
wed joints are manually tightenend and then followed by two more turns
of a suitable tool (spanner or wrench).
The EExd screwed joints are only permitted with specific cable diameters.
The table below specifies these diameters for screwed joints of the power
and feedback cables.
EExd screwed
joint
Power cable
VERSCHR-M*20,0-GER-
EX-11,0*14,3-MS-C4N-6
Feedback cable
VERSCHR-M*20,0-GER-
EX-07,5*11,9-MS-C4N-6
Fig. 11-5: Permissible cable diameter of EExd screwed joints
If MKE motors are not mounted using the cable screwed joints supplied
by INDRAMAT, then the following must be noted.
Note:
MKE motors must be mounted with cable screwed joints that
have a special test certificate complying with the B generation
of EN 50014 and EN 50018.
Screwed joint type
Mounting and Installation
MKE
Permitted cable
diameters in mm
Min.
Max.
11.0
14.3
7.5
11.9