PROBLEM
No steam is
generated
No hot water
Milk is not creamy
after texturing
Machine is not
working
Pressure Gauge is
not working
28
POSSIBLE CAUSES
• Machine is not
turned On
• Water tank is
empty
• Steam Dial is not
in STEAM/HOT
WATER dial
position
• Steam Wand is
blocked
• Empty tank
• Not enough steam
• Incorrect dose or
not enough coffee
in the filter basket.
• Using old roasted
coffee beans
beyond expiry date.
• The coffee grind is
too coarse.
WHAT TO DO
Ensure the machine is plugged in,
switched On at the power outlet and
the POWER button is pressed On.
Refer to 'Filling The Water Tank',
page 10.
Turn the STEAM/HOT WATER dial
to the STEAM position.
Use the pin on the cleaning tool to
clear the opening. If the steam wand
continues to be blocked remove
the tip of the steam wand using the
spanner in the middle of the cleaning
tool. Refer to 'Cleaning steam wand',
page 23.
Fill tank
Steam wand may be blocked. Refer to
'Cleaning steam wand', page 23.
Use cold fresh milk. Refer to
'Texturing Milk', page 18.
The safety thermal-cut may
have activated due to the pump
overheating.
Turn the machine off and allow to
cool for about
30-60 minutes.
Use the supplied 'Razor' to ensure
the correct dose of coffee in the
portafilter.
Use freshly roasted coffee within four
weeks of roasted date.
Adjust the grind to a finer setting.
Use a rubber disc and place inside
the one cup filter basket (no coffee)
and run a shot; when the needle
moves, then pressure gauge dial is
working.