Lamp SLUN-N Manual

Swing lift up mechanism pat

Advertisement

SLUN-N
For proper installation and operation, we recommend that you read and follow these instructions carefully.
● Sugatsune cannot accept any claim for damages or injuries caused by improper use of this swing lift-up stay. Please
      refer to the  Model Selection section below for the proper range of use.
● Sugatsune s liability is limited to the repair or replacement of a defective product. It shall in no way extend to the
      assembly as a whole.
● The utmost care was taken during the production of the SLUN-N. Should you however notice any defect, please
      notify your local dealer or Sugatsune (export@sugatsune.co.jp  ) .
● The warranty period extends to one year from the shipping date.
● For improvement reasons, the content of this set may be changed without prior notice. We recommend that you check
      carefully the set content against the part list shown below and report any discrepancy to your local dealer before 
      installation.
● Operating temperature is 5〜35℃. Function may vary depending on the temperature.
 
   Do not force the door open past its fully opened position.
!
 
   Do not use in excessively hot environment such as to hide an oven.
!
 
   Do not insert your hand or finger between the arms as this may lead to sever injury.
!
 
   Never attempt to open or disassemble the mechanism as this may lead to injury.
!
 
   Do not pull the arm down as it will spring back up violently and may cause serious injuries.
!
Parts list
Arm A
Fig.1
①SLUN-N(R) right-
   hand side body
          1pcs
 Binding tapping screw(3.5×15)
⑤Damper
⑥Holder
⑦Distance plate
   2pcs
 2pcs
        2pcs
*SLUB Bars are available in 4 standard sizes : 535、835、551 and 851mm.
⑧Countersunk tapping screw(3.5×20)
6pcs
Model slection
W
= Cabinet width
0  
 T
= Cabinet side panel thickness 
    
 h   = Cabinet inside height
 t
Fig.2
= Cabinet top board thickness
     
= Door width
H
= Door height
0
t
1
h
T
1
 
SWING LIFT UP MECHANISM  
Arm A
③Mounting plate
②SLUN-N(L) left-  
        2pcs
   hand side body
           1pcs
Arm B
Arm B
16pcs
Length of guide bar : L
⑨SLUB
Applicable door weight:
Door size:
SLUN-3N
2.8〜3.8 kg
Width (W
Height (H
SLUN-4N
3.8〜4.8 kg
SLUN-5N
4.8〜5.8 kg
Select the SLUN type according to the weight of the door (including 
the handle).
SLUB bar needs to be cut depending on the cabinet width W
side panel thickness T. 
Bar length L will depend on whether it is installed on Arm A or Arm B 
(see Fig.1).
Arm A installation: L= W
- ( T x 2 ) - 35
Arm B installation: L= W
- ( T x 2 ) - 19

Dimensions

PAT
*The drawing shows the application 
  for the cabinet with 3mm thick seal 
  gasket on front  edge.
Rubber gasket thickness A

Installation

1. Body installation:
(1) Draw a horizontal line at 354mm from the inside bottom of the cabinet.
(2) Line up the steel plate of the SLUN-N bodies ① and ② to the front of the cabinet and the line drawn in (1).
(3) Use screws ④ to secure both bodies to the cabinet.
a
a
Sold separately
3. Bar installation:
⑩Truss tapping screw
   (4.5×12) 4pcs
(1) Cut the bar to the necessary length as per instructions in the  Model Selection  section.
(2) Install the bar to either arm A or arm B depending on the dimensions selected above. Arm A installation is
        recommended for wooden doors as bar is not visible in the open position. Arm B installation is recommended    
        for glass door as bar is less visible in the closed position.
⑧Countersunk  tapping
screw(3.5×20)
)
600、900mm
1
)
390〜450mm
1
⑥Holder
⑦Distance plate
Fig.7

Adjustment

 and 
0
① Loosen both a screws
② Adjust height by turn b screw
③ Refasten both a screws securely
① Loosen both c screws
② Adjust door position
③ Refasten both c screws securely
① Loosen both a screws
② Turn screw  d left to bring the top of
the door closer to the cabinet
③ Refasten both a screws securely
2012.12 PRINTED IN JAPAN 0541-3 
167.5
6.5
19
(95)
9
79.5
Fig.3  Dimensions
15
 B = 244
 E = 354
32
   D = 32   +   T   -    (         
(10)
Back panel
Door
 W
(101.5)
= Cabinet width
0  
 T
= Cabinet side panel thickness
Handle
  
(45)
     h
= Cabinet inside height
  
  t   
= Cabinet top board thickness
 W
= Door width 
  C 
= Clearance (minimum 2
(3 is recommended)
2. Door installation:
(1) Install the mounting plates ③ to the back side of the door as per dimensions shown in Fig.3.
(2) Line up both a screws of each mounting plates with the slots of the arms and slide the door down.
a
* Make sure that the screws are properly inserted in the slots before releasing the door.
(3) Fasten both a screws securely.
    Do not pull the arm down as it will spring back up violently and may cause serious injuries.
!
a
Fig.5
⑤Damper
Stopper
4. Damper installation:
(1) Line the distance plate ⑦ and the holder ⑥ with the holes for the damper (Fig.7) and
        secure them with screws ⑧.
   (2) Slide the damper ⑤ into the holder from the front side.
Fig.8
Fig.9
a
b
c
a
 Spring strength adjustment:
Turn the screw at the back of stay body to 
adjust the spring strength.
d
 
  Spring strength should be adjusted similarly on both units.
!
 
  Do not set the spring strength too high as the door may    
!
     open violently and damage the system.
c
Clearance
(minimum2 . 4)
23.5
+   t   -    C + ( h - 354 )
 
W
W
 
0
1
)         
     2       
.
4)
 
 
D ( D distance to door edge )
④Binding
tapping screw
(3.5×15)
Fig.4
⑩Truss tapping
  screw(4.5×12)
06835
⑨SLUB
(A)
Fig.6
(B)
Fig.10
① Loosen both e screws on both sides
② Adjust height of the opened door
similarly on  both sides.
③ Refasten both e screws securely
e
Fig.11
-
+

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLUN-N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Slun-3nSlun-4nSlun-5n

Table of Contents