Horizon Fitness H-100 User Manual page 22

Fuel cell stack
Table of Contents

Advertisement

STEP 8:
Connect the controller to a stabilized power supply through the "13V DC" connectors (8A).
The external power supply is required to be 13V(±1V), <5A.
STEP 9:
Connect the Hydrogen supply to the hydrogen supply valve, and make sure the hydrogen pressure
is between 0.45-0.55Bar.
Warning:The tube between the hydrogen pressure regulator and the fuel cell gas input is
required to be less than 30cm.The inner diameter of this tube is required to be more than
3mm. The input pressure to the stack is required to be 0.45-0.55Bar .
Make sure the dry Hydrogen gas to be used is ≥99.995% purity and no sulphuric composition or
other gases such as CO or CH4, and also no pungent odor, paint and perfume are allowed around
stack. They all can poison the fuel cell, reducing its performance dramatically.
STEP 10:
Check the following steps before starting the system:
1.
The connection between the hydrogen input valve and the hydrogen source.
2.
The connection between the hydrogen input valve and the stack intput.
3.
The connection between the stack outoput and the purging valve.
4.
The purging valve output tube is kept away from the stack.
5.
The 8pin plug connections between the stack and the controller.
6.
The "FC+/-" connection between the stack and controller.
7.
The hydrogen input pressure is 0.45-0.55Bar.
8.
The external power is providing 12-14V.
9.
The load is below 100W.
Manual_FCS-C100_V2.2_EN
The System is now setup and ready to be used
8A
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

H-500

Table of Contents