Adrian Adriano
February 3, 2025
My washer has a problem.. when i try to use the spin. It doest open the drain. And then the pulsaror will turn without the tub turning.. only pulsator is spinning. The tub doesn't move.
1 comments:
Mr. Anderson
February 10, 2025
The issue could be due to a defective brake lever assembly or a problem with the drain pump. If the pulsator spins but the tub does not move, the brake lever assembly may need to be replaced. Additionally, if the drain does not open during the spin cycle, check for foreign matter in the drain hose, a deformed valve bellow, disconnected pump lead wire, or a defective control circuit board. Repair or replace the faulty components as needed.
ABNORMAL CONDITION When the washer is abnormal, the washer stops as the every actions turns off, beep tone sounds ON-0.1 second and OFF-0.1 second for 6 seconds and number window LED display abnormal code. The washer judges the following six conditions as abnormal condition. 1) Abnormal condition of water supply In supplying with water, the water level does not reach extra low level within 10 minutes or does not reach your chosen water level within 20 minutes.
Page 3
The digital tube displays the fault code "Ed2", accompanied by a whistle sound. • First check whether the reactor is in good contact • Replace the computer main control board 8) The display board cannot receive the main control signal. The digital tube displays the fault code "...
Page 4
Water temperature sensor failure EC2 The digital tube displays the fault code "EC2" • First check whether the connection between the main control board and the water temperature sensor is good • Replace the heating tube or the computer main control board to test whether the function is normal 16) Heating pipe failure E6C or E7C The digital tube displays the fault code "E6C"...
CIRCUIT DIAGRAM WVIID1058BKG COLOR SYMBOL GRAY BLUE GREEN BLACK LIGHT BLUE BROWN ORANGE PINK WVWD1050&950&850BKG WHITE YELLOW VIOLET THOUBLESHOOTING TROUBLE INSPECTION INSPECTION CAUSES REMEDY a. Power Source Any indications Is fuse blown? Deterioration of fuse. Replace. and beep do not Motor is defective.
TROUBLE INSPECTION INSPECTION CAUSES REMEDY b. Water Supply Water does not Does humming Something on the filter of flow when the noise come on the water valve or hose Clean the filter. power switch is from water joint assembly. start valve?...
Page 7
TROUBLE INSPECTION INSPECTION CAUSES REMEDY c. Wash/Rinse ’ Bearing ass y is defective. Replace. Washing cycle does Does the spin tub Poor connect of not start even if rotated normally Replace. connectors water keeps the when the Thermostat on motor is selected water level.
TROUBLE INSPECTION INSPECTION INSPECTION CAUSES REMEDY ’ Repair or replace. Drain takes time too Drain hose ass y is deformed. long. Hose is connected in the Repair. wrong way. Note: In draining, the water lever sensor can Note: In draining, the water level sensor can Hose is too long or position of Repair.
Page 9
TROUBLE INSPECTION INSPECTION INSPECTION CAUSES REMEDY Operation of safety device Start of spin-drying. Safety device work. Normal spin. Electric circuit works to stop Electric circuit spin when safety device counts operation detects continuously three of safety device. times of abnormal swing of spin drum.
Page 10
TROUBLE INSPECTION INSPECTION CAUSES REMEDY Buzzing/rattling Does some noise Belt is slipping. Adjust. during washing sound during Pulley is loose. Tighten. or rinsing. spin drying? Some part touch motor Repair or replace Something underneath Remove. pulsator. ’ Pulsator is rubbing. Adjust bearing ass ’...
Need help?
Do you have a question about the WVIID1058BKG and is the answer not in the manual?
Questions and answers
My washer has a problem.. when i try to use the spin. It doest open the drain. And then the pulsaror will turn without the tub turning.. only pulsator is spinning. The tub doesn't move.
The issue could be due to a defective brake lever assembly or a problem with the drain pump. If the pulsator spins but the tub does not move, the brake lever assembly may need to be replaced. Additionally, if the drain does not open during the spin cycle, check for foreign matter in the drain hose, a deformed valve bellow, disconnected pump lead wire, or a defective control circuit board. Repair or replace the faulty components as needed.
This answer is automatically generated