YILMAZ DK 502 User Manual page 32

Table of Contents

Advertisement

Available languages

Available languages

USAGE OF BUTTONS ON CONTROL PANEL (DK 504):
Emergency Stop Button (PICTURE 6 NO.128) : When the Emergency Stop button is pressed, all pneumatic electric
components of the machine return to their original position.
System Start Button (PICTURE 6 NO.129) : Used to start the welding operation
Braking button (PICTURE 6 NO.139) : When the button on the brake release handle is pressed, brakes are disengaged.
Thus moving head can be positioned manually at the desired location. When moving head is positioned, release the button
on brake release handle. Brakes are automatically engaged again, and the position of moving head is fixed.
Welding pressure adjustment (PICTURE 6 NO.141) : Isıtılarak kaynak yapılacak parçaların kaynak basıncını ayarlar.
Fabrika çıkış ayarı 6 bardır. Bu ayar değiştirilmek istendiğinde anahtarı sağa veya sola çevirmek sureti ile istenen basınca
ayarlayınız. Konumu kilitlemek için anahtarın dış çerçevesini aşağıya bastırınız
Welding pressure display (PICTURE 6 NO.143): It reads the welding pressure force in Bar.
Clamp pressure adsustment (PICTURE 6 NO.142) : It adjusts the pressure force of the clamps, which clamp the PVC
profiles to be welded. It is pre-set to 4 Bar. This adjustment is made in the same way like the welding pressure
7.2.1 Sİngle Corner and Angle Weldıng Operatıon:
Tek köşe ve açılı kaynak sabit kafada yapılabilir. Hareketli kafa açısızdır.
Open the power and air supply units.
 Check whether the brake button located on the movable head (PICTURE 7 / 1-2) is "OFF". If the brake button is not in
"OFF" position, the machine will not work.
2
adjustment.
1
PICTURE-7