6.1.8 Other Approvals; Emc And Environmental Type Tests - Siemens SIMATIC NET RUGGEDCOM RX1512 Installation Manual

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1512:
Table of Contents

Advertisement

Certification
6.1.8 Other Approvals
A copy of the Material Declaration is available online at
support.industry.siemens.com/cs/ww/en/view/109738831.
6.1.8
Other Approvals
This device meets the requirements of the following additional standards:
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RX1512 has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Test for IEC 61850-3
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
40
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic
Information Products
IEEE 1613
IEEE Standard Environmental and Testing Requirements for Communications
Networking Devices in Electric Power Substations
IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity
for Industrial Environments
IEC 61850-3
Communication Networks and Systems in Substations – Part 3: General
Requirements
Test
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced
(Conducted) RFI
Description
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal ports
DC Power Ports
Earth ground ports
Signal ports
DC Power Ports
Signal ports
DC Power Ports
Earth ground ports
https://
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 2 kV Line-to-Ground
± 2 kV Line-to-Line
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
10 V
RUGGEDCOM RX1512
Installation Manual, 04/2021, C79000-G8976-1057-20
Severity
Levels
4
a
Note
4
4
3