PennBarry ZQ165 Quick Start Manual

PennBarry ZQ165 Quick Start Manual

Ventilation fan

Advertisement

Quick Links

TM
READ AND SAVE
THESE INSTRUCTIONS
Installer: Leave this manual with
the homeowner.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as
a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, includ-
ing fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the
local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling
installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS
PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the
blower assembly (includes motor and impeller).
OPERATION
Use an on/off switch or speed control to operate this ventilator. See "Connect Wiring" for details. Use of speed controls other than PennBarry
supplied models may cause a motor humming noise.
VENTILATION FAN
MODEL ZQ165
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the ZQ165 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PennBarry ZQ165

  • Page 1 The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller). OPERATION Use an on/off switch or speed control to operate this ventilator. See “Connect Wiring” for details. Use of speed controls other than PennBarry supplied models may cause a motor humming noise.
  • Page 2 VENTILATION FAN MODEL ZQ165 Page 2 TYPICAL INSTALLATIONS Housing mounted anywhere between trusses using Housing hanger bars. mounted to I-joists. Use I-joist spacer block (provided). PLAN THE INSTALLATION Housing mounted COOKING AREA anywhere Do not install above or between inside this area.
  • Page 3 VENTILATION FAN MODEL ZQ165 Page 3 INSTALL HOUSING & DUCT 1a. Mount To ensure a noise-free mount: Secure hang- housing to ing bars together with joist. SCREWS and use a SPACER pliers to crimp mount- Hold housing (use for ing channels tightly...
  • Page 4 VENTILATION FAN MODEL ZQ165 Page 4 CONNECT WIRING INSTALL GRILLE 6. Attach grille to housing. Squeeze grille springs and insert them into tabs on each side of housing. 7. Push grille against ceiling. WIRNG PLATE & SCREW SCREW FROM PARTS 4.