Scholl CP 330 Instructions For Use Manual

Scholl CP 330 Instructions For Use Manual

Built-in hot or cold combiplate for central cooling system

Advertisement

GBA C 6001 12 E
Instructions for Use
Hot or cold combiplate
Built-in unit
Model-No.
Art. No.
CP 330
C 6001
CP 330 RAL
C 6002
CP 660
C 6005
CP 660 RAL
C 6006
CP 990
C 6009
CP 990 RAL
C 6010
Scholl Apparatebau GmbH & Co. KG
Zinhainer Weg 4
D–56470 Bad Marienberg/Germany
Phone
+0049 (0) 2661 – 9868-10
Fax
+0049 (0) 2661 – 9868-38 (Service)
Internet
www.scholl-gastro.de
E-mail
info@scholl-gastro.de
BA
Last revised 05-2021
Built-in unit for
central cooling system
Model-No.
Art. No.
CPZ 330
C 6003
CPZ 330 RAL
C 6004
CPZ 660
C 6007
CPZ 660 RAL
C 6008
CPZ 990
C 6011
CPZ 990 RAL
C 6012
Page 1 of 26
Table top
Model-No.
Art. No.
CPA 330 W
C 6106
CPA 330 SI
C 6107
CPA 330 S
C 6108
CPA 660 W
C 6109
CPA 660 S
C 6110
Mai 5, 2021
Rev. 12

Advertisement

Table of Contents
loading

Summary of Contents for Scholl CP 330

  • Page 1 CPA 660 S C 6110 CP 990 RAL C 6010 CPZ 990 RAL C 6012 Scholl Apparatebau GmbH & Co. KG Zinhainer Weg 4 D–56470 Bad Marienberg/Germany Phone +0049 (0) 2661 – 9868-10 +0049 (0) 2661 – 9868-38 (Service) Internet www.scholl-gastro.de...
  • Page 2: Table Of Contents

    GBA C 6001 12 E ABLE OF CONTENTS Table of contents ............................... 2 Preface ................................4 General ..............................5 Information about the user manual ....................5 Liability and warranty........................5 Copyright ............................6 Declaration of conformity ........................ 6 Safety ................................. 7 General .............................
  • Page 3 GBA C 6001 12 E Installation and electric connection ....................16 5.2.1 Installation of the hot or cold combiplate (only valid for installation variants) ......16 5.2.2 Electrical connections ........................ 17 Operation ............................17 5.3.1 Control panel ..........................18 Cleaning and maintenance ........................19 Safety instructions for cleaning......................
  • Page 4: Preface

    REFACE Congratulations! In purchasing this new SCHOLL appliance you have chosen a product which meets highest technical stand- ards while providing outstanding convenience in practical use. This appliance has been designed with minimal energy consumption in mind. Used responsibly, it will serve you well in an ecologically sound manner.
  • Page 5: General

    GBA C 6001 12 E ENERAL NFORMATION ABOUT THE USER MANUAL This user manual describes the installation, operation and maintenance of the device and serves as an im- portant source of information and reference. The knowledge of all safety and handling instructions contained in the user manual creates the conditions for the safe and proper operation of this device.
  • Page 6: Copyright

    GBA C 6001 12 E OPYRIGHT The user manual, including any text, drawings, images and other depictions, is protected by copy-right. Reproduction in any manner and form - including excerpts - as well as the utilization and/or communication of the content is forbidden without permission in writing from the manufacturer. Any non-compliance is liable for damages.
  • Page 7: Safety

    GBA C 6001 12 E AFETY This section provides an overview of all-important safety aspects. In addition, each chapter provides precise safety instructions for the prevention of dangers which are marked with symbols. Moreover, the pictograms, signs and labels found on the device are to be observed and kept in legible condition.
  • Page 8: Intended Use

    GBA C 6001 12 E NTENDED USE The reliability of the device is only guaranteed if used properly in accordance with the specifications in the user manual. Any technical interventions, assembly and maintenance are to be made by qualified service personnel. The hot or cold combiplate is for keeping dishes warm or cool (not for warming or cooling) of prepared dishes.
  • Page 9: Transport, Packaging And Storage

    GBA C 6001 12 E RANSPORT PACKAGING AND STORAGE RANSPORT INSPECTION The delivery must be checked immediately upon receipt for completeness and transport damage. In case of visible transport damage, do not accept the delivery, or only do so conditionally. The extent of the damage on the transport has to be marked on the documents / delivery note.
  • Page 10: Technical Data

    ECHNICAL DATA ECHNICAL SPECIFICATIONS 4.1.1 B UILT IN HOT OR COLD COMBIPLATE Built-in hot or cold combiplate Model-No. CP 330 CP 330 RAL CP 660 CP 660 RAL CP 990 CP 990 RAL Art.-No. C 6001 C 6002 C 6005...
  • Page 11: Built-In Hot Or Cold Combiplate For Central Cooling System

    GBA C 6001 12 E 4.1.2 B UILT IN HOT OR COLD COMBIPLATE FOR CENTRAL COOLING SYSTEM Built-in hot or cold combiplate for central cooling system Model-No. CPZ 330 CPZ 330 RAL CPZ 660 CPZ 660 RAL CPZ 990 CPZ 990 RAL Art.-No.
  • Page 12 GBA C 6001 12 E 4.1.3 T ABLE TOP HOT OR COLD COMBIPLATE Table top hot or cold combiplate Model-No. CPA 330 W CPA 330 SI CPA 330 S CPA 660 W CPA 660 S Art.-No. C 6106 C 6107 C 6108 C 6109 C 6110...
  • Page 13: Product Diagram

    GBA C 6001 12 E RODUCT DIAGRAM 4.2.1 B UILT IN HOT OR COLD COMBIPLATE Figure size 1 x 1/1 GN 4.2.2 B UILT IN HOT OR COLD COMBIPLATE FOR CENTRAL COOLING SYSTEM Figure size 1 x 1/1 GN Page 13 of 26 Mai 5, 2021 Last revised 05-2021 Rev.
  • Page 14 GBA C 6001 12 E 4.2.3 T ABLE TOP HOT OR COLD COMBIPLATE Figure size 1 x 1/1 GN Page 14 of 26 Mai 5, 2021 Last revised 05-2021 Rev. 12...
  • Page 15: Installation And Operation

    GBA C 6001 12 E NSTALLATION AND OPERATION AFETY INFORMATION WARNING! Risk of electrocution! The device must be installed by qualified professionals.  Device may cause injuries due to improper installation!  Before installation, check the data of the local power grid with the technical specifications of the unit (see nameplate).
  • Page 16: Installation And Electric Connection

    GBA C 6001 12 E NSTALLATION AND ELECTRIC CONNECTION 5.2.1 I NSTALLATION OF THE HOT OR COLD COMBIPLATE ONLY VALID FOR INSTALLATION VARIANTS  Put your device on a level and safe surface which stands the weight of the device. ...
  • Page 17: Electrical Connections

    GBA C 6001 12 E 5.2.2 E LECTRICAL CONNECTIONS  The socket circuit must be secured according to the performance details.  Connect the controller to the circuit board.  Plug the Schuko plug into the socket. Printed circuit board only for the following devices: C 6001, C 6002, C 6005, C 6006, C 6009, C 6010 PERATION ...
  • Page 18: Control Panel

    GBA C 6001 12 E 5.3.1 C ONTROL PANEL The hot or cold combiplate can be set and operated via the touch control panel mounted on the front. The five buttons are used for adjusting settings, switching (between heating or cooling mode), quick choice between preset values, as well as parameterization.
  • Page 19: Cleaning And Maintenance

    GBA C 6001 12 E LEANING AND MAINTENANCE AFETY INSTRUCTIONS FOR CLEANING  Before cleaning and before repairing, disconnect the device from the outlet (pull the plug!) and al- low it cool.  Do not use caustic cleaning agents and make sure that no water seeps into the device. ...
  • Page 20: Safety Instructions For Maintenance

    GBA C 6001 12 E AFETY INSTRUCTIONS FOR MAINTENANCE  Check the main cable for damage from time to time. Do not use the device if the cable is damaged. If the cable is damaged, it must be replaced by customer service or a qualified electrician to avoid risks.
  • Page 21: Possible Malfunctions

    GBA C 6001 12 E OSSIBLE MALFUNCTIONS Problem Cause Remedy • Power plug not plugged in • Pull out the plug and insert it properly correctly • Fuse of the power supply has • Check fuse, test unit on a differ- No function tripped ent elec.
  • Page 22: Disposal

    GBA C 6001 12 E ISPOSAL Old equipment Your old device must be disposed of at the end of its service life in accordance with local regulations. It is advisable to contact a specialised waste management company, or to contact the local disposal service in your community.
  • Page 23: Installation Drawings

    GBA C 6001 12 E NSTALLATION DRAWINGS Dimensioned drawings are available upon request. EMPERATURE CONTROLLER HOT OR COLD COMBIPLATE Dimensions Cut-out size Page 23 of 26 Mai 5, 2021 Last revised 05-2021 Rev. 12...
  • Page 24: Circuit Diagrams

    GBA C 6001 12 E IRCUIT DIAGRAMS Circuit diagrams are available upon request. Page 24 of 26 Mai 5, 2021 Last revised 05-2021 Rev. 12...
  • Page 25: Warranty And Service

    GBA C 6001 12 E ARRANTY AND SERVICE 11.1 W ARRANTY CONDITIONS The manufacturer accepts no liability or warranty in the following cases:  failure to observe notes and instructions given in the Instructions for Use;  use of the product in a manner not conforming to its intended use; ...
  • Page 26: Service Address

    7:00 a.m. till 4:00 p.m. Fridays from 7:00 a.m. till 12:15 p.m. Outside these office hours please communicate your requests per e-mail or telefax. Scholl Apparatebau GmbH & Co. KG Zinhainer Weg 4 D-56470 Bad Marienberg/Germany Phone 0049 (0)2661/9868-10...

Table of Contents