Built-In Test Program - TC Electronic ATAC Service Manual

Hide thumbs Also See for ATAC:
Table of Contents

Advertisement

Built-in Test Program:

The ATAC has a Built-in Test Program. Use the program to narrow down problems
with keys, encoders, LED's etc.
To run the program; press UNDO while powering up.
Follow the instructions on the display.
To leave the Built-in Test Program; turn off power.
ATAC Built-in Test Program Version 1.01 has following tests:
1.
Display
2.
Midi connection (automatic, uses internal relay)
Notice: Midi functions are not implemented in software version 1.24 or lower.
3.
Remote connection (automatic, uses internal relay)
4.
Keys
5.
Encoders (dial knobs)
6.
LED's (indicators)
7.
Voltages
______________________________________________________________________________________________________________________________________________________________________________
________________
TC Electronic A/S
The voltage labels refers to labels in schematics. Some voltages are attenuated to protect
the test circuit. When measuring manually, measurements must take place before the
attenuators (marked with dash lines in schematics) to match the above voltage limits.
Voltage limits in automatic voltage test:
Voltage label
U-PSIN:
U-REMIN:
U+5V:
U-NEGATIV:
U-CONT:
U-BATT:
UCC-PCMCIA1:
UCC-PCMCIA2:
CC-PCMCIA3:
* U-REMIN will fail test, if D13 is removed. See part list.
ATAC Service manual
limits
+7.5 to +15.5 VDC
+4.7 to +5.1 VDC *
+2.17 to 2.25 VDC
-14.2 to -12.8 VDC
-8.67 to -7.83 VDC
+3.0 to +4.0 VDC
0.0 to +0.3 VDC
+4.8 to +5.0 VDC
+11.4 to +12.4 VDC
page 6