Napoleon B36NTR Installation And Operating Instructions Manual page 37

Hide thumbs Also See for B36NTR:
Table of Contents

Advertisement

Available languages

Available languages

37
33 7/8"
2" 51mm
86cm
EN
35 1/2"
[90.2cm]
16"
Do not put objects in front of the
40.6cm
appliance (minimum distance of 4 feet)
B36 / GX36-1 HORIZONTAL VENT SECTIONS: A minimum of 1" (25mm) at the bottom and sides, and 3"
(76.2mm) at the top of the vent pipe on all horizontal runs to combustibles is required. Use firestop spacer W010-
3440 (supplied).
NOTE: The minimum clearances from the top of the horizontal vent pipe to combustible materials
may be reduced from 3" (76.2mm) to 1" (25mm) with the B36 OR 2" (50.8mm) with the GX36-1 in those
installations with a minimum 38" (96.5cm) vertical vent rise made immediately off the appliance collar.
B36 / GX36-1 VERTICAL VENT SECTIONS: A minimum of 1" (25mm) all around the vent pipe on all vertical
runs to combustibles is required except for clearances in appliance enclosures. Vertical runs within the enclosure
must maintain a 3" (76.2mm) clearance from combustibles. See "minimum enclosure clearances" sections for
both B36 and GX36-1 models. Use firestop spacer W500-0096 (not supplied).
W415-1678 / E / 08.15.18