Carlisle BINKS DEVILBISS HAR-600 Service Manual

Regulator and gauge, regulator

Advertisement

Quick Links

SERVICE MANUAL
EN
IMPORTANT:
Read and follow all instructions and SAFETY PRECAUTIONS before
using this equipment. Retain for future reference.
Risk of personal injury.
Risk of property damage.
Except as otherwise specified by the manufacturer, this product
is specifically designed for compressed air service and use
with any other fluid (liquid or gas) is a misapplication. For
example, use with or injection of certain hazardous gases in
the system (such as oxygen or liquid pertroleum gas) could
be harmful to the unit or result in a combustible condition
that may cause fire or explosion. Manufacturer's warranties
are void in the event of misapplication and manufacturer as-
sumes no responsibility for any resulting loss.
Risk of injury. Release all air pressure from system before
servicing system. Be sure to read and understand all Service
Bulletins on the separate components before using the system.
Use only specified DeVilbiss parts.
It is the Customer's responsibility to have all operators and service personnel read and understand this manual.
Contact your local Carlisle Fluid Technologies representative for additional copies of this manual.
SB-6-147-R2 (1/2021)
HAR-600 AIR REGULATOR AND GAUGE
HAR-507 AIR REGULATOR
IMPORTANT! DO NOT DESTROY
READ ALL INSTRUCTIONS BEFORE OPERATING THIS PRODUCT.
DESCRIPTION
This regulator has been designed to receive air at main line pressure
and to deliver it at a desired lower regulated pressure.
Specifications
Air inlet
Air outlets
Air Capacity
Maximum Temp.
Max. Inlet Pressure
Regulator range
INSTALLATION
1. Maximum inlet pressure and operating temperature ratings are
250 psig and 150° F (intermittent to 180° F).
2. Install as close as possible to where regulated air is needed.
3. Install the unit with the air flowing through the body in the direc-
tion indicated by the arrow.
4. Install the same pipe size unit as the pipe line in use. Avoid using
fittings, couplings, etc., that restrict the air flow, unless maximum
flow is not needed.
5. Regulator may be installed so that adjusting handle is in any
position. Attach gauge to one 1/4" female port.
6. Turning the adjusting screw clockwise increases the regulated
pressure and turning it counterclockwise reduces the regulated
pressure.
1 / 4
3/8" NPT(F)
1/4" NPT(F) (3 Ea.)
60 CFM
150° F
250 psi
0-125 psi
www.carlisleft.com

Advertisement

loading

Summary of Contents for Carlisle BINKS DEVILBISS HAR-600

  • Page 1 IMPORTANT! DO NOT DESTROY It is the Customer's responsibility to have all operators and service personnel read and understand this manual. Contact your local Carlisle Fluid Technologies representative for additional copies of this manual. READ ALL INSTRUCTIONS BEFORE OPERATING THIS PRODUCT.
  • Page 2 1/4" NPT Outlet Air Inlet 3/8" NPT 1/4" NPT Outlet PARTS LIST – Model HAR-507 Regulator Assembly PARTS LIST – Model HAR-600 Regulator and Gauge Assembly Ind. Ind. Replace. Parts Replacement Parts No. Part No. Description Req. Part No. Description Req.
  • Page 3 NOTES SB-6-147-R2 (1/2021) 3 / 4 www.carlisleft.com...
  • Page 4 This product is covered by Carlisle Fluid Technologies’ materials and workmanship limited warranty. The use of any parts or accessories, from a source other than Carlisle Fluid Technologies, will void all warranties. Failure to reasonably follow any maintenance guidance provided may invalidate any warranty.

This manual is also suitable for:

Binks devilbiss har-507