DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Directional switch is closed on initial
-02
power up.
MEMORY RECALL
NO
SYMPTOM
Control will not operate because of Static Return
Circuits valid
to Off (SRO) lock out.
for
POSSIBLE CAUSE
Traction
Forward directional switch is closed on initial
Controller
start up (i.e. closure of battery, key switch or foot
switch).
•= Return directional switch lever to neutral and
then return lever to forward position.
Forward directional switch is welded closed or
mis-adjusted to be held closed.
•= Replace or adjust directional switch to insure
that it opens when the directional switch is
returned to neutral.
Short circuit between P3 and P4.
•= Disconnect the wire from P4 and check for a
short circuit between P3 and the wire that was
connected to P4.
Defective control.
•= Replace the controller unit.
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Travel enable switch is closed on initial
-03
power up.
MEMORY RECALL
NO
SYMPTOM
Control will not operate because of Static Return
Circuits valid
to Off (SRO) lock out.
for
POSSIBLE CAUSE
Traction
Reverse directional switch is closed on initial
Controller
start up (i.e. closure of battery, key switch or
foot/deadman switch).
•= Return directional switch lever to neutral and
then return lever to reverse position.
Reverse directional switch is welded closed or
mis-adjusted to be held closed.
•= Replace or adjust directional switch to insure
that it opens when the directional switch is
returned to neutral.
Short circuit between P3 and P5.
•= Disconnect the wire from P5 and check for a
short circuit between P3 and the wire that was
connected to P5.
Defective control. Replace the controller unit.
CORRECTIVE ACTIONS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when P4 is greater
than 12% of battery voltage at initial key switch on.
TROUBLE-SHOOTING DIAGRAM
KEY
SWITCH
L
P1
P17
P2
P6
CAUSE OF STATUS INDICATION
This status code will be displayed when P5 is greater
than 12% of battery voltage at initial key switch on.
TROUBLE-SHOOTING DIAGRAM
KEY
SWITCH
L
P1
P17
P2
P6
Page 17
P3
P4
P5
P3
P4
P5
April 1999