Available Functions And Settings; Selecting Functions Using The Remote Controller - Mitsubishi Electric SUZ-KA24NAHZ Service Manual

Hide thumbs Also See for SUZ-KA24NAHZ:
Table of Contents

Advertisement

(2) Functions available when setting the unit number to 01-03 or AL (07 in the case of the IR wireless remote controller)
• When setting functions for an indoor unit in an independent system, set the unit number to 01 referring to 4 setting the
indoor unit number.
• When setting functions for a simultaneous twin indoor unit system, set the unit number to 01 to 03 for each indoor
unit in the case of selecting different functions for each unit referring to 4 setting the indoor unit number.
• When setting the same functions for an entire simultaneous Twin-indoor unit system, set refrigerant address to AL
(07 in the case of the IR wireless remote controller) referring to 4 setting the indoor unit number.
<Table 3> Available functions and settings
Function
100h
Filter sign
2500h
No filter sign indicator
5/15/35/50Pa
External static pressure
(0.02/0.06/0.14/0.20in.WG)
No heater present
Heater present
SEZ, SLZ :Set temp -4.5°F ON
Heater control *2
PEAD, SVZ :Heater not operation in Defrost/Error
SEZ, SLZ :Set temp -1.8°F ON
PEAD, SVZ :Heater not operation in Defrost/Error*4
Set temperature in heating
Available
mode *3
Not available
Fan speed during the
Extra low
heating thermo OFF
Stop
Set fan speed
Fan speed during the
Set fan speed
cooling thermo OFF
Stop
Detection of abnormality of
Available
the pipe temperature (P8)
Not available
*2 For the detail of Heater control, refer to the service manual.
*3 4 degC (7.2 degF) up
*4 Depend on the error, heater may not operate please refer to SVZ service manual.
External static pressure setting for SVZ (Vertical, Horizontal left, Horizontal right position*).
Setting No.
External static
pressure
Mode No. 08 Mode No. 10
75Pa (0.3in.WG)
1
125Pa (0.5in.WG)
2
200Pa (0.8in.WG)
3
* Regarding to down flow setting, please refer to down flow kit installation manual.
External static pressure setting for PEAD.
Setting No.
External static
pressure
Mode No. 08 Mode No. 10
35Pa (0.14in.WG)
2
50Pa (0.20in.WG)
3
70Pa (0.28in.WG)
1
100Pa (0.40in.WG)
2
3
150Pa (0.60in.WG)

12-2. SELECTING FUNCTIONS USING THE REMOTE CONTROLLER

Refer to "15-3. SERVICE MENU" and "15-5. FUNCTION SETTING" when selecting functions.
OCH754A
Settings
: Initial setting
Check
( Factory setting )
1
1
1
: Initial setting
Check
( Factory setting )
1
1
2
2
2
77
Mode
: Initial setting
No.
( Factory setting )
Setting
Wired remote
No.
Ceiling suspended
controller
(RF thermostat)
PEAD-A·AA
1
07
2
(107)
3
08
Refer to the
(108)
table below
10
Refer to the
(110)
table below
1
11
(111)
2
1
23
(123)
2
24
1
(124)
2
1
25
2
(125)
3
1
27
(127)
2
1
28
(128)
2
Check
Multi position
SVZ-KP·NA
Refer to the
table below
Refer to the
table below