Beckhoff PS1111-2403-0000 Documentation

Beckhoff PS1111-2403-0000 Documentation

Hide thumbs Also See for PS1111-2403-0000:

Advertisement

Quick Links

Documentation | EN
PS1111-2403-0000
Power supply 24 V DC, 3.8 A, 1-phase
2020-10-28 | Version: 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff PS1111-2403-0000

  • Page 1 Documentation | EN PS1111-2403-0000 Power supply 24 V DC, 3.8 A, 1-phase 2020-10-28 | Version: 1.0...
  • Page 3: Table Of Contents

    4 Application notes............................. 26 Charging batteries ........................... 26 Series connection .......................... 26 Parallel use to increase power ...................... 26 Operation on two phases......................... 26 Use in a tightly sealed enclosure ..................... 26 5 Appendix .............................. 28 Documentation issue status ...................... 28 Support and Service ........................ 29 PS1111-2403-0000 Version: 1.0...
  • Page 4 Table of contents Version: 1.0 PS1111-2403-0000...
  • Page 5: Overview

    • Full power between -10°C and +60°C • Large screw terminals The PS1111-2403-0000 power supply is a single-phase 24V power supply with an output current of 3.8A. On the input side, the device has a wide-range input and an input inrush current limitation.
  • Page 6: Foreword

    , XFC , XTS and XPlanar are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners.
  • Page 7: Safety Instructions

    All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG. Personnel qualification This description is only intended for trained specialists in control, automation and drive engineering who are familiar with the applicable national standards.
  • Page 8 Foreword Safety instructions and installation requirements for the PS1111-2403-0000 power supply DANGER Danger of electric shock, fire, injuries, injuries resulting in death! • Do not use the power supply without proper grounding (protective conductor). Use the terminal at the in- put terminal strip for the earth connection, not one of the screws on the housing.
  • Page 9: Terminology And Abbreviations

    50 Hz. AC 120 V parameters are valid for a mains frequency of 60 Hz. A keyword indicating a choice without implied preference. shall A keyword indicating a mandatory requirement. should A keyword indicating a choice with a clearly preferred method of implementation. PS1111-2403-0000 Version: 1.0...
  • Page 10: Technical Data, Mounting, Wiring

    At 24V, 3.8A constant current load, 2mF load capaci- tance, see Fig. Switch-on behavior definitions Turn-on overshoot Max. 100 mV 100 mV 100 mV See Fig. Switch-on behavior definitions Fig. 1: Input voltage range; switch-on behavior definitions Fig. 2: Input current over output current; power factor over output current Version: 1.0 PS1111-2403-0000...
  • Page 11: Dc Input

    Technical data, mounting, wiring DC input Do not operate this power supply with DC input voltage! PS1111-2403-0000 Version: 1.0...
  • Page 12: Input Inrush Current

    Inrush energy Max. 0.3A 0.4A 1.7A At +40°C, cold start Fig. 3: Switch-on behavior at nominal load, typ., 230Vac@25°C; zoom inrush current surge Fig. 4: Switch-on behavior at nominal load, typ., 120Vac@25°C; zoom inrush current surge Version: 1.0 PS1111-2403-0000...
  • Page 13: Output

    It does not matter whether the power supply is switched on or off. The absorbed energy can be calculated by means of the built-in large-size output capacitor. Fig. 5: Output voltage over output current, typ.; short circuit at the output. PS1111-2403-0000 Version: 1.0...
  • Page 14: Hold-Up Time

    Typ. 14ms 25ms 119ms At 24V, 3.8A Typ. 40ms 60ms 242ms At 24V, 1.9A Min. 11.5ms 20ms 95ms At 24V, 3.8A Min. 32ms 48ms 194ms At 24V, 1.9A Fig. 6: Hold-up time over input voltage; switch-off behavior, definitions Version: 1.0 PS1111-2403-0000...
  • Page 15: Efficiency And Losses

    75% of the nominal load during 25% of the time and 100% of the nominal load during the remaining time. Fig. 7: Efficiency over output current; losses over output current Fig. 8: Efficiency over input voltage; losses over input voltage PS1111-2403-0000 Version: 1.0...
  • Page 16: Functional Wiring Diagram

    Technical data, mounting, wiring Functional wiring diagram Fig. 9: Functional wiring diagram Version: 1.0 PS1111-2403-0000...
  • Page 17: Front Side And Operating Elements

    Technical data, mounting, wiring Front side and operating elements Fig. 10: Front PS1111-2403-0000 Input terminals (screw terminals) Designation (A) Description Mains input N Mains input L Protective conductor, PE Output terminals (screw terminals) Designation (B) Description two identical positive poles, positive output...
  • Page 18: Terminals And Wiring

     max. 4mm² a*: max. 4mm² (d<2.8mm) Connection cross section e*: AWG 20-10 (AWG) f*: AWG 20-10 a* AWG 20-10 (d<2.8mm) Strip length 7mm / 0.28inch e* = solid wire f* = stranded wire a* = with ferrule Version: 1.0 PS1111-2403-0000...
  • Page 19: Lifetime Expectancy

    At 24V, 3.8A and 40°C; Ground Benign GB40 217F 1,042,000h 1,055,000h 977,000h At 24V, 3.8A and 25°C; Ground Benign GB25 210,000h 215,000h 211,000h At 24V, 3.8A and 40°C; Ground Fixed GF40 276,000h 282,000h 281,000h At 24V, 3.8A and 25°C; Ground Fixed GF25 PS1111-2403-0000 Version: 1.0...
  • Page 20: Emc

    Class B CISPR 22 Harmonic input current EN 61000-3-2 Class A requirements met Voltage fluctuations, flicker EN 61000-3-3 Met, tested with non-pulsating constant current loads. Switching frequencies Main converter 5kHz to 120kHz Input load and output voltage dependent Version: 1.0 PS1111-2403-0000...
  • Page 21: Environment

    The derating is not hardware-controlled. The user must take this into account in order to stay below the reduced current limits, so that device overload is avoided. Fig. 11: Output current over ambient temperature; output current over installation altitude PS1111-2403-0000 Version: 1.0...
  • Page 22: Protective Functions And Safety Features

    At 230Vac, 50Hz, TN, TT / IT network Max. 40µA / 70µA At 110Vac, 50Hz, TN, TT / IT network Max. 50µA / 110µA At 132Vac, 60Hz, TN, TT / IT network Max. 90µA / 180µA At 264Vac, 50Hz, TN, TT / IT network Version: 1.0 PS1111-2403-0000...
  • Page 23: Dielectric Strength

    > 2mA > 6mA We recommend connecting either the positive or the negative pole to the protective conductor system. This avoids situations in which the load starts unexpectedly or cannot be disconnected if an unnoticed earth leakage occurs. PS1111-2403-0000 Version: 1.0...
  • Page 24: Declaration Of Conformity And Approvals

    Technical data, mounting, wiring 3.16 Declaration of conformity and approvals EU declaration of conformity UL Certificate: UL 61010-1/2-201 Applicable for US and Canada UL Certificate: NEC CLASS 2 Version: 1.0 PS1111-2403-0000...
  • Page 25: Dimensions And Weight

    High-quality polycarbonate/ABS blend material Installation clearances See chapter on Safety instructions and installation requirements [} 8] Ingress protection Small parts such as screws, nuts etc. with a diameter of more than 4.2 mm. Fig. 13: Front/side view PS1111-2403-0000, all specifications in mm PS1111-2403-0000 Version: 1.0...
  • Page 26: Application Notes

    The temperature sensor in the housing is positioned at the center on the right side of the power supply with a distance of 1cm. The following measurement results can be used as reference for estimating the temperature rise inside the housing. Version: 1.0 PS1111-2403-0000...
  • Page 27 PK 9516 100, plastic PK 9516 100, plastic Input voltage 230Vac 230Vac Load 24V, 3.04A; (=80%) 24V, 3.8A; (=100%) Temperature inside 30.3°C 31.7 °C the housing Temperature outside 21.0°C 21.0°C the housing Temperature 9.3K 10.7 K increase PS1111-2403-0000 Version: 1.0...
  • Page 28: Appendix

    Appendix Appendix Documentation issue status Version Comment - First public issue - Addenda & corrections - Preliminary documentation for PS1111-2403-0000 Version: 1.0 PS1111-2403-0000...
  • Page 29: Support And Service

    Please contact your Beckhoff branch office or representative for local support and service on Beckhoff products! The addresses of Beckhoff's branch offices and representatives round the world can be found on her internet pages: https://www.beckhoff.com/english/beckhoff/world.htm You will also find further documentation for Beckhoff components there.
  • Page 31 More Information: www.beckhoff.com/ps1111-2403-0000 Beckhoff Automation GmbH & Co. KG Hülshorstweg 20 33415 Verl Germany Phone: +49 5246 9630 info@beckhoff.com www.beckhoff.com...

Table of Contents