Carrying In The Outdoor Unit - Toshiba MMY-MAP0726FT6P-UL Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

▼ Combination of outdoor units
Model name
Unit 1
(Standard Model)
Header unit
MMY-MAP0726FT6P-UL
MMY-MAP0726*
MMY-MAP0966FT6P-UL
MMY-MAP0966*
MMY-MAP1206FT6P-UL
MMY-MAP1206*
MMY-MAP1446FT6P-UL
MMY-MAP1446*
MMY-MAP1686FT6P-UL
MMY-MAP1686*
MMY-AP1926FT6P-UL
MMY-MAP0966*
MMY-AP2166FT6P-UL
MMY-MAP1206*
MMY-AP2406FT6P-UL
MMY-MAP1446*
MMY-AP2646FT6P-UL
MMY-MAP1446*
MMY-AP2886FT6P-UL
MMY-MAP1446*
MMY-AP3126FT6P-UL
MMY-MAP1686*
MMY-AP3366FT6P-UL
MMY-MAP1206*
MMY-AP3606FT6P-UL
MMY-MAP1206*
MMY-AP3846FT6P-UL
MMY-MAP1446*
MMY-AP4086FT6P-UL
MMY-MAP1446*
MMY-AP4326FT6P-UL
MMY-MAP1446*
MMY-AP4566FT6P-UL
MMY-MAP1686*
Model name
Unit 1
(Space Saving Model)
Header unit
MMY-AP192S6FT6P-UL
MMY-MAP1206*
MMY-AP240S6FT6P-UL
MMY-MAP1206*
MMY-AP288S6FT6P-UL
MMY-MAP1686*
MMY-AP336S6FT6P-UL
MMY-MAP1686*
5

Carrying in the outdoor unit

CAUTION
Handle the outdoor unit carefully, observing the following items.
To use a forklift or other machinery for loading/unloading in transportation, insert the fork of the forklift into the
rectangular holes for handling as shown below.
To lift up the unit, insert a rope capable of bearing the weight of the unit into the rectangular holes shown below.
Tie the unit from 4 sides.
(Apply padding in positions where the rope comes in contact with the outdoor unit so that no damage is caused
to the outer surface of the outdoor unit.)
(There are reinforcing plates on the side surfaces, so the rope cannot be passed through.)
Side
Rectangular
holes for
handling
Incorrect
Front/Back
Correct
Fork of the
forklift
9-EN
1122001001-2_EN-FR.indb 5
1122001001-2_EN-FR.indb 5
Unit 2
Unit 3
Follower unit
Follower unit
MMY-MAP0966*
MMY-MAP0966*
MMY-MAP0966*
MMY-MAP1206*
MMY-MAP1446*
MMY-MAP1446*
MMY-MAP1206*
MMY-MAP0966*
MMY-MAP1206*
MMY-MAP1206*
MMY-MAP1206*
MMY-MAP1206*
MMY-MAP1446*
MMY-MAP1206*
MMY-MAP1446*
MMY-MAP1446*
MMY-MAP1446*
MMY-MAP1446*
Unit 2
Unit 3
Follower unit
Follower unit
MMY-MAP0726*
MMY-MAP1206*
MMY-MAP1206*
MMY-MAP1686*
Correct
Incorrect
Incorrect
Plaster
board
Rope
Plaster
board
Rectangular
Reinforcing
holes for
plate
lifting
– 5 –
■ Weight center and weight
◆ Weight center of an outdoor unit
(A)
Anchor bolt position
(B)
27.6" (700)
X
No.
Model type
(A)
MAP0726FT6P-UL
MAP0966FT6P-UL
(B)
MAP1206FT6P-UL
MAP1446FT6P-UL
(C)
MAP1686FT6P-UL
Anchor bolt position
(C)
Anchor bolt position
36.2" (920)
51.6" (1310)
X
X
Y
Z
(in(mm))
(in(mm))
(in(mm))
20.5" (520)
15.4" (390)
24.0" (610)
23.8" (605)
15.7" (400)
23.2" (590)
30.3" (770)
16.3" (415)
22.4" (570)
Unit: in (mm)
X
Weight
(lb(kg))
615 (279)
736 (334)
875 (397)
10-EN
2/18/17 11:44 AM
2/18/17 11:44 AM

Hide quick links:

Advertisement

Table of Contents
loading