Vega VEGACAL 69 Operating Instructions Manual page 51

Capacitive double rod electrode for level measurement
Hide thumbs Also See for VEGACAL 69:
Table of Contents

Advertisement

Ʋ Closing cap
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
Ʋ Stranded wire with end sleeve
Electromechanical data - version IP66/IP68 (1 bar)
Options of the cable entry
Ʋ Cable gland with integrated connec-
tion cable
Ʋ Cable entry
Ʋ Blind plug
Connection cable
Ʋ Wire cross-section
Ʋ Wire resistance
Ʋ Tensile strength
Ʋ Standard length
Ʋ Max. length
Ʋ Min. bending radius
Ʋ Diameter
Ʋ Colour - Non-Ex version
Ʋ Colour - Ex-version
Display and adjustment module
Voltage supply and data transmission
Indication
Adjustment elements
Protection rating
Ʋ unassembled
Ʋ Mounted into the sensor without cover IP40
Ambient temperature - Display and
adjustment module
Material
Ʋ Housing
Ʋ Inspection window
Voltage supply
Operating voltage U
B
Operating voltage U
B
switched on
Reverse voltage protection
VEGACAL 69 • Two-wire 4 ... 20 mA/HART
with lighting
½ NPT
0.2 ... 2.5 mm² (AWG 24 ... 14)
0.2 ... 1.5 mm² (AWG 24 ... 16)
M20 x 1.5 (cable: ø 5 ... 9 mm)
½ NPT
M20 x 1.5; ½ NPT
0.5 mm² (AWG 20)
< 0.036 Ω/m
< 1200 N (270 lbf)
5 m (16.4 ft)
180 m (590.6 ft)
25 mm (0.984 in) with 25 °C (77 °F)
approx. 8 mm (0.315 in)
Black
Blue
through the sensor
LC display in dot matrix
4 keys
IP20
-20 ... +70 °C (-4 ... +158 °F)
ABS
Polyester foil
12 ... 36 V DC
20 ... 36 V DC
Integrated
11 Supplement
51