Dell OptiPlex GXi Reference And Installation Manual page 101

Mini tower systems
Hide thumbs Also See for OptiPlex GXi:
Table of Contents

Advertisement

Message
The loaded card is not
a category card. Press
OK to proceed.
No more DMA values can
be added.
No more interrupt val-
ues can be added.
No more memory values
can be added.
No more I/O port val-
ues can be added.
NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary in the online System User's Guide.
Table B-1. Configuration Utility Messages (continued)
Probable Cause
The category you have
chosen is not the correct cat-
egory under which to add
this card.
No more values are avail-
able for the resource you are
trying to add or modify.
Corrective Action
Select OK. The ICU automatically opens the
correct category's dialog box. Continue the pro-
cedure for adding the card as described in
"Adding a Listed Card" or "Adding an Unlisted
Card" in Chapter 3.
The maximum number of values for each
resource is as follows:
4 DMA channels
7 IRQ lines
9 memory address blocks
20 I/O ports
To free values for the resource you are trying to
add or modify, delete some of the values listed
in the resource box for the card. If your card
requires all of the values listed, contact your
card manufacturer to resolve the issue.